Related Experiment Video
Updated: Sep 11, 2025

The Use of Mixed Reality in Custom-Made Revision Hip Arthroplasty: A First Case Report
Published on: August 4, 2022
Total knee arthroplasty with fracture of polyethylene post
Bryanna McGowan1, Cheng Zhou1, Hyunji Shim1
1Loyola University Medical Center and Loyola Univeristy Chicago, Maywood, IL, USA.
Abstract:
A total knee arthroplasty (TKA) is a common procedure performed in patients with symptomatic osteoarthritis that is refractory to conservative management. The use of polyethylene in prostheses has become the standard in many types of arthroplasties with improved longevity and increased patient satisfaction. We present a case of a rare postoperative complication of polyethylene post fracture detected on CT imaging in a patient who had a primary posterior stabilized total knee arthroplasty (TKA) performed several years prior.