Calibration method of line-structured light based on direction and length constraints
Summary
This study introduces an accurate line-structured light calibration method for industrial measurement. The new approach improves light plane fitting and measurement accuracy, enhancing 3D reconstruction in manufacturing.
Area of Science:
- Metrology
- Computer Vision
- Industrial Automation
Background:
- Line-structured light vision technology is crucial for industrial measurement.
- Calibration accuracy of light planes directly impacts measurement performance.
- Increasing precision demands in manufacturing require enhanced calibration methods.
Purpose of the Study:
- To propose an accurate line-structured light calibration method.
- To improve the precision of light plane calibration for industrial applications.
- To enable more accurate 3D reconstruction in manufacturing settings.
Main Methods:
- Establishing direction and length constraints between camera optical center, target feature points, and laser control points.
- Utilizing double constraints and camera internal parameters for direct 3D coordinate computation.
- Avoiding reliance on external camera parameters for calibration.
Main Results:
- The proposed method achieves superior light plane fitting accuracy compared to traditional methods.
- Demonstrates enhanced measurement accuracy in experimental evaluations.
- Successfully applied to 3D reconstruction of cutting points on steel plates.
Conclusions:
- The developed method offers a significant improvement in line-structured light calibration.
- It addresses the need for higher accuracy in precision manufacturing.
- The technique shows considerable practical value for industrial 3D reconstruction tasks.
Related Concept Videos
Calibration Curves: Linear Least Squares
2.2K
A calibration curve is a plot of the instrument's response against a series of known concentrations of a substance. This curve is used to set the instrument response levels, using the substance and its concentrations as standards. Alternatively, or additionally, an equation is fitted to the calibration curve plot and subsequently used to calculate the unknown concentrations of other samples reliably.
For data that follow a straight line, the standard method for fitting is the linear...
For data that follow a straight line, the standard method for fitting is the linear...
2.2K
Design Example: Measuring Distance Between Two Points with Obstructions
119
When measuring distances in areas with physical obstructions, such as a lake in a field, surveyors must employ techniques to calculate accurate lengths without direct line measurements. One effective method is the offset technique, which allows for precise distance estimation over inaccessible stretches.In this scenario, a surveyor must measure a side of an area that crosses a lake. Since the measuring tape cannot span the lake, the surveyor begins by establishing a baseline that aligns with...
119
Confocal Fluorescence Microscopy
14.3K
Confocal microscopy is an advanced microscopic technique. The prime advantage of the confocal microscope over other microscopy techniques is its ability to block the out-of-focus light from the illuminated samples using pinholes. It is widely used with fluorescence optics to obtain high-resolution, sharp contrast images. Unlike optical microscopes, confocal microscopes use a focused beam of light laser to scan the entire sample surface at different z-planes. These microscopes are, therefore,...
14.3K