Related Experiment Video
Updated: Sep 11, 2025

Detecting Pre-Stimulus Source-Level Effects on Object Perception with Magnetoencephalography
Published on: July 26, 2019
Optimising the sensitivity of optically-pumped magnetometer magnetoencephalography to gamma band electrophysiological
Ryan M Hill1,2, Holly Schofield1,2, Elena Boto1,2
1Sir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, University Park, Nottingham, United Kingdom.
Abstract:
The measurement of electrophysiology is of critical importance to our understanding of brain function. However, current non-invasive measurements-electroencephalography (EEG) and magnetoencephalography (MEG)-have limited sensitivity, particularly compared to invasive recordings. Optically-Pumped Magnetometers (OPMs) are a new type of magnetic field sensor which ostensibly promise MEG systems with higher sensitivity; however, the noise floor of current OPMs remains high compared to cryogenic instrumentation and this limits the achievable signal-to-noise ratio of OPM-MEG recordings. Here, we investigate how sensor array design affects sensitivity, and whether judicious sensor placement could compensate for the higher noise floor. Through theoretical analyses, simulations, and experiments, we use a beamformer framework to show that increasing the total signal measured by an OPM array-either by increasing the number of sensors and channels, or by optimising the placement of those sensors-affords a linearly proportional increase in signal-to-noise ratio (SNR) following beamformer reconstruction. Our experimental measurements confirm this finding, showing that by changing sensor locations in a 90-channel array, we could increase the SNR of visual gamma oscillations from 4.8 to 10.5. Using a 180-channel optimised OPM-array, we capture broadband gamma oscillations induced by a naturalistic visual paradigm, with an SNR of 3; a value that compares favourably to similar measures made using conventional MEG. Our findings show how an OPM-MEG array can be optimised to measure brain electrophysiology with the highest possible sensitivity. This is important for the design of future OPM-based instrumentation.
More Related Videos
10:22Interictal High Frequency Oscillations Detected with Simultaneous Magnetoencephalography and Electroencephalography as Biomarker of Pediatric Epilepsy
Published on: December 6, 2016
07:52Multiscale Investigations of Cortical Processing by Integrating Laminar Polytrodes and Optogenetics with Micro Electrocorticography in Rodents
Published on: May 23, 2025