Related Experiment Video
Updated: Sep 11, 2025

Integration of 5G Experimentation Infrastructures into a Multi-Site NFV Ecosystem
Published on: February 3, 2021
FFT-RDNet: A Time-Frequency-Domain-Based Intrusion Detection Model for IoT Security
Bingjie Xiang1, Renguang Zheng2, Kunsan Zhang2
1School of Ocean Informattion Engineering, Jimei University, Xiamen 361000, China.
Abstract:
Resource-constrained Internet of Things (IoT) devices demand efficient and robust intrusion detection systems (IDSs) to counter evolving cyber threats. The traditional IDS models, however, struggle with high computational complexity and inadequate feature extraction, limiting their accuracy and generalizability in IoT environments. To address this, we propose FFT-RDNet, a lightweight IDS framework leveraging depthwise separable convolution and frequency-domain feature fusion. An ADASYN-Tomek Links hybrid strategy first addresses class imbalances. The core innovation of FFT-RDNet lies in its novel two-dimensional spatial feature modeling approach, realized through a dedicated dual-path feature embedding module. One branch extracts discriminative statistical features in the time domain, while the other branch transforms the data into the frequency domain via Fast Fourier Transform (FFT) to capture the essential energy distribution characteristics. These time-frequency domain features are fused to construct a two-dimensional feature space, which is then processed by a streamlined residual network using depthwise separable convolution. This network effectively captures complex periodic attack patterns with minimal computational overhead. Comprehensive evaluation on the NSL-KDD and CIC-IDS2018 datasets shows that FFT-RDNet outperforms state-of-the-art neural network IDSs across accuracy, precision, recall, and F1 score (improvements: 0.22-1%). Crucially, it achieves superior accuracy with a significantly reduced computational complexity, demonstrating high efficiency for resource-constrained IoT security deployments.
Related Concept Videos
Radial System Protection
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
Reclosers and Fuses
A comprehensive protection scheme for radial distribution...
IR Frequency Region: Fingerprint Region
Attenuated Total Reflectance (ATR) Infrared Spectroscopy: Overview
The ATR process begins by directing a beam...
Line Protection with Impedance Relays
Under normal conditions, low load currents keep the measured...
Rapidly Varying Flow

