Related Experiment Video
Updated: Sep 11, 2025

Experimental Methods for Investigation of Shape Memory Based Elastocaloric Cooling Processes and Model Validation
Published on: May 2, 2016
Thermal Imaging and Infrared Thermometry to Assess Post-wash Cooling: Method Development and Standardization
Maheshvari N Patel1,2, Nayan Patel1, Apeksha Merja3
1Clinical Research, NovoBliss Research Private Limited, Ahmedabad, IND.
None:
The cooling sensation imparted by topical rinse-off formulations, such as facial cleansers, represents a critical sensorial attribute influencing consumer perception and product acceptability. Despite its subjective nature, this effect can be objectively quantified using non-invasive tools such as infrared (IR) thermography and non-contact infrared thermometry. The aim was to develop and internally standardize a reproducible methodology for assessing the immediate cooling effect of rinse-off facial products using IR thermal imaging and non-contact infrared temperature measurement. An exploratory, non-randomized, open-label, crossover evaluation was conducted on 20 healthy male volunteers (aged 22-40 years). Each participant underwent facial skin temperature assessments at three predefined time points: baseline (resting state), post-exercise (to elevate skin temperature physiologically), and immediately after facial cleansing. The test arm involved application of a commercial rinse-off face wash, while the control arm followed cleansing with water only. Facial skin surface temperature was recorded using both a high-resolution IR thermographic camera and a point-based non-contact infrared thermometer. A statistically significant reduction in mean facial skin temperature was observed post-exercise in both the test and control arms, suggesting localized evaporative cooling. Following product application, the test arm demonstrated a more pronounced decrease in temperature compared to the control. Notably, IR thermography captured broader, region-specific thermal variations and greater magnitude of change than non-contact thermometry, which registered only minor point-specific differences. The findings support the feasibility and sensitivity of infrared thermography as a robust, objective technique for evaluating the immediate cooling effects of rinse-off cosmetic products. This internally standardized method may be reliably applied in future clinical research to substantiate thermoregulatory or sensorial efficacy claims associated with topical formulations. Specifically, its application may aid in the comparative assessment of novel cooling agents, guide formulation optimization, and support regulatory submissions or marketing claims related to cooling efficacy in both dermatological and cosmetic product development.
Related Concept Videos
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Calorimetry
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Physical Methods for Controlling Microbial Growth: Temperature
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Thermal expansion and Thermal stress: Problem Solving
To solve the problem, first, identify the known and unknown quantities. The initial length (L) of the bridge is 1275 m, the coefficient of linear expansion (α) for steel is 12 x 10-6/°C, and the change in...

