Extending pulse phase durations during ECAP recordings to optimise perceived loudness
Tobias Raffelsberger1, Kathrin Lauss2, Thomas Rasse1
1Klinikum Wels-Grieskirchen, Wels, Austria.
International Journal of Audiology
|August 14, 2025
Summary
Adjusting pulse phase duration (PD) in cochlear implant (CI) electrical compound action potential (ECAP) tests can improve user comfort. Longer PDs reduce loudness perception, benefiting sensitive CI users.
Area of Science:
- Audiology
- Biomedical Engineering
- Neuroscience
Background:
- Cochlear implants (CI) use electrical compound action potentials (ECAPs) to assess neural response.
- Loudness sensitivity can limit ECAP measurement efficacy.
- Optimizing stimulation parameters like pulse phase duration (PD) may enhance user tolerance and data quality.
Purpose of the Study:
- To investigate the impact of varying pulse phase durations (PDs) on ECAP thresholds, loudness perception, and measurement success rates in CI users.
- To determine if adjusting PD can improve tolerance for ECAP measurements.
Main Methods:
- ECAP measurements were performed using AutoART software with PDs ranging from 30 to 100 µs.
- Loudness perception was evaluated alongside ECAP measurements.
- Twenty MED-EL CI users participated in the study.
Main Results:
- Longer PDs (80 & 100 µs) allowed higher maximum stimulation charges and were perceived as less loud.
- Both ECAP and perceptual thresholds increased with longer PDs.
- ECAP threshold determination rates remained consistent across tested PDs.
Conclusions:
- Increasing pulse phase duration in ECAP measurements can decrease loudness discomfort for CI users.
- This adjustment offers a potential benefit for sensitive CI users in clinical audiology settings.
Related Concept Videos
Korotkoff Sounds
13.3K
Korotkoff sounds are the specific sounds heard while measuring blood pressure using a sphygmomanometer, typically with a stethoscope or a Doppler device. They are named after Russian physician Nikolai Korotkov, who first described them in 1905. These sounds correspond to turbulent blood flow in the artery as the blood pressure cuff is gradually released after inflation.
During blood pressure assessment, inflating the cuff 30 millimeters of mercury above the patient's systolic blood pressure...
During blood pressure assessment, inflating the cuff 30 millimeters of mercury above the patient's systolic blood pressure...
13.3K
Echo
1.2K
The human ear cannot distinguish between two sources of sound if they happen to reach within a specific time interval, typically 0.1 seconds apart. More than this, and they are perceived as separate sources.
Imagine the sound is reflected back to the ears. Assuming that the source is very close to the human, the difference between hearing the two sounds—the emitted sound and the reflected sound—may be more than the minimum time for perceiving distinct sounds. If this is the case,...
Imagine the sound is reflected back to the ears. Assuming that the source is very close to the human, the difference between hearing the two sounds—the emitted sound and the reflected sound—may be more than the minimum time for perceiving distinct sounds. If this is the case,...
1.2K
Double Resonance Techniques: Overview
870
Double resonance techniques in Nuclear Magnetic Resonance (NMR) spectroscopy involve the simultaneous application of two different frequencies or radiofrequency pulses to manipulate and observe two distinct nuclear spins. One important application of double resonance is spin decoupling, which selectively suppresses coupling with one type of nucleus while observing the NMR signal from another nucleus, simplifying the spectrum and enhancing resolution.
Spin decoupling is usually achieved by...
Spin decoupling is usually achieved by...
870
Instrumentation Amplifier
1.3K
An electrocardiography (ECG) machine is an essential piece of medical equipment used to monitor the electrical activity of the heart. It operates by detecting small electrical changes on the skin that result from the depolarization of the heart muscle during each heartbeat. However, these signals are in the microvolt range and can be easily overwhelmed by noise or interference.
To overcome this challenge, an ECG machine utilizes an instrumentation amplifier. This specialized amplifier is...
To overcome this challenge, an ECG machine utilizes an instrumentation amplifier. This specialized amplifier is...
1.3K