Related Experiment Video
Updated: Sep 11, 2025

Measurements of Soil Carbon by Neutron-Gamma Analysis in Static and Scanning Modes
Published on: August 24, 2017
Study on the 241Am-Be neutron reference radiation field established at CAEP
Song Zhang1, Da-Jie Ding1, Ben-Jiang Mao1
1Institute of Nuclear Physics and Chemistry, China Academy of Engineering Physics, No. 64, Mianshan Road, Youxian District, Mianyang 621999, Sichuan, China.
Abstract:
In order to evaluate the field characteristics and instrument calibration capability of the 241Am-Be neutron reference radiation field at China Academy of Engineering Physics (CAEP), this paper conducted a series of researches on the radiation field. Firstly, the neutron energy spectrum of the field was investigated by multi-sphere spectrometer and Geant4. Secondly, the quantity transmission from China Institute of Atomic Energy (CIAE) to CAEP was achieved through the precision long counter system. In addition, three neutron dose rate meters from different manufacturers were calibrated in both the fields at CAEP and CIAE. Finally, the uncertainty of calibration factor for each instrument was calculated and validated in the two fields. The results demonstrated that the room scatter in the neutron radiation reference field at CAEP meet the requirement of ISO 8529 and the neutron energy spectrum measured in the field was acceptable. The range of neutron ambient dose equivalent rate that can be produced at CAEP and its uncertainty were determined. The calibration factors and their extended uncertainties obtained using two instruments in both fields were found to be reasonable and reliable. The radiation field established at CAEP can meet the routine calibration and experiment of common neutron dose rate meters.
More Related Videos
09:18Laser-heating and Radiance Spectrometry for the Study of Nuclear Materials in Conditions Simulating a Nuclear Power Plant Accident
Published on: December 14, 2017
06:28Visualization of Low-Level Gamma Radiation Sources Using a Low-Cost, High-Sensitivity, Omnidirectional Compton Camera
Published on: January 30, 2020
Related Concept Videos
Atomic Emission Spectroscopy: Overview
Atomic Emission Spectroscopy: Lab
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing...
Atomic Absorption Spectroscopy: Radiation and Light Sources
Two common narrow-range 'line' sources used in AAS are hollow-cathode lamps (HCLs) and...
Atomic Emission Spectroscopy: Instrumentation
Atomic Absorption Spectroscopy: Overview
When irradiated by EMR of a particular wavelength, these...