Related Experiment Video
Updated: Sep 10, 2025

Screening for Endocrine Activity in Water Using Commercially-available In Vitro Transactivation Bioassays
Published on: December 4, 2016
Aptamer-based ratiometric fluorescent platform for selective detection of 17β-estradiol in environmental water
Yue Wang1, Xiaoqian Yuan1, Shenao Qu1
1Henan Linker Technology Key Laboratory, College of Advanced Interdisciplinary Science and Technology (CAIST), Henan University of Technology, Zhengzhou 450001, China. linglibu@163.com.
Abstract:
17β-estradiol (E2), a potent endocrine-disrupting chemical, is frequently detected in aquatic environments and food samples, where it poses serious ecological and public health risks even at trace levels. Herein, we report a label-free ratiometric fluorescent aptasensor for the sensitive and selective detection of E2, employing ethyl violet (EV) as a near-infrared (NIR) responsive dye and fluorescein (FL) as an internal reference. EV was identified through systematic screening based on its strong fluorescence response upon aptamer binding. The resulting sensor exhibited a pronounced ratiometric response, a low detection limit of 0.25 μM, and excellent selectivity against structural analogues. Its practical performance was validated using farm wastewater samples, yielding recoveries of 94.92-110.49% and relative standard deviations below 6.15%. With an estimated cost of approximately $0.11, this aptasensor provides a simple, economical, and reliable tool for monitoring estrogenic pollutants in complex environmental water samples.