Related Experiment Video
Updated: Sep 10, 2025

Author Spotlight: Advancing Awake Nasotracheal Intubation with Flexible Video Rhino-Laryngoscopes
Published on: August 2, 2024
A periscope-based, 3D printed indirect laryngoscope for resource limited settings: a non-randomized observational
Phillip R Schmitt1, Samantha Maguire2, Eliza Sternlicht3
1Warren Alpert Medical School, Brown University, Providence, RI, USA. phillip_schmitt@brown.edu.
Background:
In the United States and other resource-rich settings, video laryngoscopy is often favored for emergency intubation over direct laryngoscopy due to ease of use and improved performance in difficult airways. Video laryngoscopes pose a significant cost barrier against adoption in low- and middle-income countries (LMICs). In this study, we designed and tested a low-cost, 3D printable, periscope-based laryngoscope that achieves an indirect view of the vocal cords without the use of a video camera. The absence of expensive video components allows this device to be manufactured for $4.41 USD, making it well-suited for resource-limited settings.
Methods:
The periscope-based laryngoscope was manufactured from polylactic acid (PLA) filament using a 3D printer. Manikin testing of the laryngoscope was performed by providers ranging from medical students to experienced physicians using the high fidelity Laerdal SimMan®. The novel laryngoscope was compared to commonly available direct and video laryngoscopes, and intubation times and first-pass success rates were recorded.
Results:
A total of 121 trials were performed. In experienced intubators, faster intubation times were seen in the direct and periscope-based laryngoscopes compared to video laryngoscopes. Mean intubation times for experienced intubators were as follows: Direct Laryngoscope = 17.45 s, Video Laryngoscope = 23.34 s, and Novel Periscope-based Laryngoscope = 11.31 s, with statistical significance (p < 0.001) found between the Video and Periscope-based laryngoscope times. 100% of trials resulted in successful intubation of the trachea.
Conclusion:
The periscope-based laryngoscope yielded intubation times and first-pass success rates that compare favorably to direct and video laryngoscopes, and it can be readily manufactured in multiple environments at a low price point without proprietary industrial technology. Next steps include human clinical trials and regulatory approvals prior to clinical adoption of the novel device.
Related Concept Videos
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques
Suctioning the Oropharyngeal Airway
After assembling the equipment, the nurse should practice hand hygiene and don appropriate PPE according to infection control guidelines to avoid the...
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...
Endoscopic Procedures III: Video Capsule Endoscopy
Endoscopic Studies I: Bronchoscopy and Thoracoscopy
Bronchoscopy
Description
Bronchoscopy is a procedure that involves direct visualization of the larynx, trachea, and bronchi for diagnostic and therapeutic purposes. A flexible fiber optic or rigid bronchoscope is used to carry out the procedure. The fiber-optic bronchoscope is more frequently used due...

