Gas Chromatography-Mass Spectrometry Paired with Total Vaporization Solid-Phase Microextraction as a Forensic Tool
Published on: May 25, 2021
Gas chromatography of volatile organic compounds using a micro-plasma ion source with a differential mobility
Hassan O Umar1, Gyoungil Lee1, Peter E Fowler1
1Department of Chemistry and Biochemistry, New Mexico State University, Las Cruces, NM 88003, USA.
None:
A micro-plasma ion source (MPIS) was combined with a differential mobility spectrometer as a detector for gas chromatographic measurements of volatile organic compounds (VOCs). Gas phase hydrated protons (H+(H2O)n) were produced in air at ambient pressure with a first generation MPIS embodiment and used to ionize eluting VOCs through atmospheric pressure chemical ionization (APCI) reactions. Ions formed from most VOCs were shown by mass analysis to be protonated monomers (MH+(H2O)n) and proton bound dimers (M2H+) and provided, with mobility analysis, an additional dimension for VOC characterization along with retention time. Quantitative response for thirty-six VOCs with 3 to 10 carbons from seven chemical classes was obtained using a second-generation MPIS embodiment. Response curves were characteristic of APCI reactions with a working range of ∼104 and a linear range of 10 to 50. Response factors for oxygen containing VOCs were similar for constituents within a chemical class while differences existed among chemical classes. Response curves were best for molecules with strong dipoles where detection limits were <10 pg. While MPIS is an enabling technology with ion mobility detectors for gas chromatography (GC), these findings suggest the MPIS could be used also as a stand-alone GC detector.
More Related Videos
07:57Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
11:18A Practical Guide on Coupling a Scanning Mobility Sizer and Inductively Coupled Plasma Mass Spectrometer SMPS-ICPMS
Published on: July 11, 2017
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography: Types of Detectors-II
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...