Related Experiment Video
Updated: Jun 17, 2025

Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
Ultrafast Gas Chromatography-Tandem Differential Mobility Spectrometry: Toward A New Generation of On-Site, Real-Time
Jamie A Threadgold1, Peter E Fowler2, Gary A Eiceman2
1Counter Terrorism and Security, Defence Science and Technology Laboratory, Salisbury SP4 0JQ, United Kingdom.
Abstract:
In the defense and security sector, rapid detection of trace quantities of threat materials is paramount. Traditional instrumentation typically relies on standalone ion mobility techniques due to being inexpensive, portable, and highly sensitive. However, these techniques face limitations when handling complex samples, suffering from low resolving power (often less than 100) and ion-suppression effects, which can lead to false-positive and false-negative results. Here, we present a foundation to the solution through the hyphenation of the flow field thermal gradient gas chromatograph (FF-TG-GC) developed by HyperChrom with a tandem differential ion mobility spectrometer (DMS-DMS) developed in-house at New Mexico State University. The FF-TG-GC demonstrates the ability to separate a variety of nitroaromatic compounds of explosive significance in 20 s using a nitrogen carrier gas, highlighting the potential to offer selectivity advantages without substantially compromising high-throughput demands. These selectivity advantages are illustrated by the successful application of the FF-TG-GC-DMS-DMS to the detection and identification of single-nanogram loadings of 18 explosives and related substances in the presence of interfering materials, such as lactic acid, musk, and diesel. Furthermore, the system is capable of mitigating in-source ion-suppression effects by chromatographic separation of target analytes from background interference prior to ionization.
More Related Videos
05:31Gas Chromatography-Mass Spectrometry Paired with Total Vaporization Solid-Phase Microextraction as a Forensic Tool
Published on: May 25, 2021
11:14Rapid High-throughput Species Identification of Botanical Material Using Direct Analysis in Real Time High Resolution Mass Spectrometry
Published on: October 2, 2016
Related Concept Videos
Tandem Mass Spectrometry
Secondary fragmentations occur in the interaction cell and can be induced by various factors. Fragmentation induced by collision with inert gases, such as N2, Ar, He, etc., is called collision-induced...
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...