DCE-UNet: a transformer-based fully automated segmentation network for multiple adolescent spinal disorders in x-ray
Zhilong Xue1, Shuangcheng Deng1, Yiqun Yue1
1Beijing Institute of Petrochemical Technology, Qingyuan North Road, No. 19, Daxing District, Beijing, 102617, People's Republic of China.
None:
In recent years, spinal x-ray image segmentation has played a vital role in the computer-aided diagnosis of various adolescent spinal disorders. However, due to the complex morphology of lesions and the fact that most existing methods are tailored to single-disease scenarios, current segmentation networks struggle to balance local detail preservation and global structural understanding across different disease types. As a result, they often suffer from limited accuracy, insufficient robustness, and poor adaptability. To address these challenges, we propose a novel fully automated spinal segmentation network, DCE-UNet, which integrates the local modeling strength of convolutional neural networks (CNNs) with the global contextual awareness of Transformers. The network introduces several architectural and feature fusion innovations. Specifically, a lightweight Transformer module is incorporated in the encoder to model high-level semantic features and enhance global contextual understanding. In the decoder, a Rec-Block module combining residual convolution and channel attention is designed to improve feature reconstruction and multi-scale fusion during the upsampling process. Additionally, the downsampling feature extraction path integrates a novel DC-Block that fuses channel and spatial attention mechanisms, enhancing the network's ability to represent complex lesion structures. Experiments conducted on a self-constructed large-scale multi-disease adolescent spinal x-ray dataset demonstrate that DCE-UNet achieves a Dice score of 91.3%, a mean Intersection over Union (mIoU) of 84.1, and a Hausdorff Distance (HD) of 4.007, outperforming several state-of-the-art comparison networks. Validation on real segmentation tasks further confirms that DCE-UNet delivers consistently superior performance across various lesion regions, highlighting its strong adaptability to multiple pathologies and promising potential for clinical application.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...