Related Experiment Video
Updated: Sep 10, 2025

Luminescence Resonance Energy Transfer to Study Conformational Changes in Membrane Proteins Expressed in Mammalian Cells
Published on: September 16, 2014
Unraveling Ratiometric Chemiluminescence Probe: Theoretical Insights into pH Modulation, Luminescence Dynamics, and
Shuangqi Pi1, Ya-Jun Liu1,2
1Department of Chemistry, Faculty of Arts and Sciences, Center for Advanced Materials Research, Beijing Normal University, Zhuhai, 519087, P. R. China.
None:
Maintaining a stable physiological pH is essential for the normal functioning of both whole organisms and individual cells. Ratiometric chemiluminescence probes have been widely employed to monitor pH in cells and living organisms due to their high sensitivity, resistance to external interferences, and noninvasiveness. In this study, the working mechanism of a specific ratiometric chemiluminescent probe, Ratio-pHCL-1, is investigated using (time-dependent) density functional theory. The mechanism can be divided into three stages. At first, pH influences the protonation state of Ratio-pHCL-1 in physiological pH range of 6.8-8.4. Subsequently, Ratio-pHCL-1 decomposes to generate the light emitter in the first excited state (S1) via a gradually reversible charge-transfer initiated luminescence mechanism. Finally, at higher pH values, the intramolecular energy transfer (ET) occurs, resulting in a redshift of the emission wavelength. The redshift of the emission wavelength effectively enhances the luminescence intensity and improves the imaging ability. While at lower pH values, the ET process does not occur. This is the first systematic study on the working mechanism of ratiometric chemiluminescent probes at the molecular and electronic-state levels. The findings can also be extended to understand the mechanism of a class of ratiometric chemiluminescent probes.
Related Concept Videos
Photoluminescence: Applications
Variables Affecting Phosphorescence and Fluorescence
Photoluminescence: Fluorescence and Phosphorescence
A pair of electrons in a...
Fluorescence and Phosphorescence: Instrumentation
Protein Dynamics in Living Cells
Fluorescent recovery after photobleaching (FRAP) is a fluorescent-protein-based detection technique used to quantify protein movement rates within the cell. This method exposes a small portion of the cell to an intense laser beam. The laser beam causes permanent photobleaching of the fluorophore-tagged proteins in the exposed region. As the bleached...

