Thermal Effects of Pulsed Infrared Lasers on Zirconia Implants at Different Temperatures In Vitro
George Kokkinos1, Maryam Hafeez1, Joseph De Leon1
1Laboratory for Periodontal-, Implant- and Phototherapy (LA-PIP), Department of Periodontics and Endodontics, School of Dental Medicine, Stony Brook University, Stony Brook, NY 11794, USA.
None:
Objectives: The aim of this study was to determine the differential temperature produced on ceramic implants using laser irradiation on a pulsed setting of intrabony defects in vitro. Methods: A ceramic (Zr) dental implant (Zeramex, 4.8 × 12 mm) was placed into a bovine bone block. A three-wall intrabony defect (6 × 4 × 3 mm) was created to mimic an osseous peri-implant defect. Thermocouples were placed on the apical and coronal areas to measure temperature changes (∆T) during 60 s of laser irradiation. The bovine block was heated to 37 °C, and the defect walls were irradiated with the CO2 and Er,Cr:YSGG laser. The settings used were pulsed mode for both lasers, with 30 Hz and 1.5 W for the Er,Cr:YSGG laser and 70 Hz and 2 W for the CO2 laser. The same laser settings were repeated at room temperature (RT, 23 °C). Twenty trials were performed for each experimental group at room and body temperature for assessment of ∆T. Paired t-test were used to compare the measurements between 37 °C and 23 °C for the Er,Cr:YSGG, and CO2 laser, respectively. Results: The CO2 laser resulted in the highest ∆T (°C) at the coronal (15.22 ± 0.28/8.82 ± 0.21) and apical (5.84 ± 0.14/2.30 ± 0.28) level when this laser was used in both room temperature and body temperature, respectively. The highest ∆T (°C) for the Er,Cr:YSGG laser at body temperature at the coronal thermocouple was 7.64 ± 0.55, while for the CO2 laser, at body temperature was 8.82 ± 0.21. Conclusion: Within the limitations of our study, the use of CO2 laser and Er,Cr:YSGG laser on peri-implant defects generally appears to be safe in treating peri-implant defects around zirconia implants in vitro.
More Related Videos
Related Concept Videos
Factors Affecting Body Temperature
Factors may include:
Decreased Body Temperature
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's forehead...