Related Experiment Video
Updated: Sep 10, 2025

Shrinkage of Dental Composite in Simulated Cavity Measured with Digital Image Correlation
Published on: July 21, 2014
Evaluation of Internal and Marginal Shrinkage Stress in Adhesive Class III Cavities Restored with Different Resin
Elisa Donaria Aboucauch Grassi1, Guilherme Schmitt de Andrade2, Ana Beatriz Gomes de Carvalho1
1Department of Dental Materials and Prosthodontics, Institute of Science and Technology, São Paulo State University (UNESP), 777th Eng. Francisco José Longo Av., São José dos Campos 12245-000, SP, Brazil.
Abstract:
Objectives: To study the effects of internal and marginal polymerization shrinkage stress and distribution in different resin composite class III dental restorations in relation to the restorative technique using numerical finite element analysis (FEA). Methods: A 3D model of a human hemi-maxilla with a sound maxillary central incisor were created. Four class III distal cavities were shaped and differently restored. Four groups of resin composite combinations were analyzed: group C (three increments of conventional composite); group B (two increments of bulk-fill composite); group FC (flowable base + three increments of conventional composite); and group FB (flowable bulk-fill base + two increments of conventional composite). The resulting four models were exported to FEA software for static structural analysis. Polymerization shrinkage was simulated using thermal analogy, and stress distribution was analyzed using the Maximum Principal Stress criterion at the marginal and internal cavity interfaces. Results: Group FC showed the highest stress at the level in the proximal region (9.05 MPa), while group FB showed the lowest (4.48 MPa). FB also exhibited the highest internal dentin stress, indicating potential risks for long-term bond degradation. In the cavo-surface incisal angle, the average peak stress across all groups was 3.76 MPa. At the cervical cavo-surface angle, stress values were 3.3 MPa (C), ~3.36 MPa (B), 3.41 MPa (FC), and 3.27 MPa (FB). Conclusions: Restorative technique did not significantly influence marginal stress distribution in class III composite restorations. However, the bevel area at the cervical margin showed the highest concentration of shrinkage stress.
More Related Videos
07:42Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024
05:30Roughness Impact of Piezoelectric Dental Scaler on Two Distinct Flowable Composite Filling Materials