Related Experiment Video
Updated: Sep 10, 2025

Standardized Technique of Aortic Valve Re-implantation for Valve-sparing Aortic Root Replacement
Published on: December 11, 2017
Mid-Term Outcomes of Balloon-Expandable Aortic Valve-in-Valve Replacement in the United States
Amar Krishnaswamy1, Amr E Abbas2, Vasilis C Babaliaros3
1Cleveland Clinic, Cleveland, Ohio, USA.
Background:
Aortic valve-in-valve (AViV) replacement for is approved for patients with degenerated surgical valves at high or prohibitive surgical risk, mostly on the basis of small series with short-term follow-up.
Objectives:
The aim of this study was to analyze the outcomes of AViV therapy using contemporary balloon-expandable valves (BEVs) in a large series with mid-term outcomes.
Methods:
BEV AViV patients (June 2015 to December 2023) in the Society for Thoracic Surgeons (STS)/American College of Cardiology TVT (Transcatheter Valve Therapy) Registry were propensity matched to native transcatheter aortic valve replacement (TAVR) patients. Primary analysis included death and stroke at 5 years. Comparisons were also made on the basis of STS score, BEV subtype, and stented vs stentless index surgical valve type.
Results:
In total, 14,474 AViV patients were matched to 385,556 TAVR patients (13,638 pairs). The mean age was 74 years, and the mean STS Predicted Risk of Mortality was 6.1%. Emergency cardiac surgery (0.2%) and bioprosthetic valve fracture (22%) were infrequent. Death (43.1% vs 55.2%; P < 0.001), stroke (10.5% vs 11.8%; P < 0.001), and their composite were lower for AViV compared with TAVR at 5 years with similar findings at each STS tertile. The SAPIEN 3 Ultra RESILIA device demonstrated lower discharge echo gradients for all sizes (20 mm, 19.4 mm Hg vs 23.8 mm Hg; 23 mm, 15.1 mm Hg vs 19.2 mm Hg; 26 mm, 12.1 mm Hg vs 15.1 mm Hg; and 29 mm, 8.6 mm Hg vs 12.1 mm Hg). There was no difference in death or stroke at 5 years for stentless vs stented surgical valves (42.9% vs 46.0%; P = 0.12).
Conclusions:
This large, real-world analysis confirms the safety and durability of AViV compared with TAVR at all surgical risk levels at mid-term follow-up. Consideration may be given to broadening the indication for AViV.
More Related Videos
12:17Full-root Aortic Valve Replacement by Stentless Aortic Xenografts in Patients with Small Aortic Roots
Published on: May 21, 2017
05:31Transcatheter Pulmonary Valve Replacement from Autologous Pericardium with a Self-Expandable Nitinol Stent in an Adult Sheep Model
Published on: June 8, 2022
Related Concept Videos
Aortic Regurgitation III: Medical Management
Mitral Stenosis III: Medical Management
Aortic Regurgitation II: Clinical Features and Diagnostic Tests