Subcutaneous interstitial pressure measurement during early septic shock: an exploratory study
Auguste Dargent1,2, Isabelle Fournel3, Marine Jacquier4,5
1Lyon Sud Hospital, Anesthesia and Critical Care Department, Hospices Civils de Lyon, Lyon, France. auguste.dargent@chu-lyon.fr.
Scientific Reports
|August 27, 2025
Summary
Subcutaneous interstitial pressure (SIP) in septic shock patients was not significantly lower than in controls. However, negative SIP was more common in septic shock, suggesting a complex role in fluid overload during sepsis.
Area of Science:
- Critical Care Medicine
- Physiology
- Fluid Dynamics
Background:
- Fluid therapy is vital for septic shock but risks fluid overload.
- Capillary leakage in sepsis can lead to interstitial fluid accumulation.
- Previous models suggest reduced interstitial pressure in sepsis, but clinical data in humans is lacking.
Purpose of the Study:
- To investigate changes in subcutaneous interstitial pressure (SIP) in human sepsis.
- To determine if SIP is lower in patients with septic shock compared to controls.
Main Methods:
- Prospective observational study in an Intensive Care Unit (ICU).
- Inclusion of adult patients under sedation and mechanical ventilation with limited fluid resuscitation.
- Measurement of SIP using a subcutaneous transducer-tip probe in septic shock and control groups.
Main Results:
- No significant difference in mean SIP between septic shock (1.69 ± 2.99 mmHg) and control groups (2.51 ± 2.39 mmHg).
- Sub-atmospheric SIP was observed in 33% of septic shock patients versus 7% of controls, though not statistically significant.
- Higher fluid balance was noted in septic shock patients despite similar SIP levels.
Conclusions:
- Subcutaneous interstitial pressure is not significantly lower in human septic shock.
- Sub-atmospheric SIP may be more prevalent in septic shock, indicating potential implications for fluid dynamics.
- Further research is needed to elucidate the role of interstitial pressure in sepsis-induced capillary leakage and fluid overload.
Related Concept Videos
Measurement of Blood Pressure
1.4K
Assessing blood pressure is a standard procedure executed in virtually all medical environments. The method utilized today was established over a hundred years ago by an innovative Russian doctor, Dr. Nikolai Korotkoff. The soft ticking noise, known as Korotkoff sounds, heard while taking blood pressure readings results from turbulent blood flow within the vessels. The apparatus required for this procedure includes a sphygmomanometer, a blood pressure cuff attached to a gauge, and a...
1.4K
Sites for measruring blood pressure
2.4K
Blood pressure measurement is a fundamental clinical procedure, providing crucial data for assessing cardiovascular health. Among the various sites for this measurement, the brachial and popliteal arteries are predominantly utilized due to their accessibility and the reliability of their readings. This lesson delves into the anatomical significance, methodology, and considerations of measuring blood pressure at these locations.
The Brachial Artery: Primary Site for Blood Pressure Measurement
The Brachial Artery: Primary Site for Blood Pressure Measurement
2.4K