Construction of a Preclinical Multimodality Phantom Using Tissue-mimicking Materials for Quality Assurance in Tumor Size Measurement
Published on: July 29, 2013
Modulating CT Attenuation of Polyvinyl Alcohol Cryogels for Individualized Training Phantoms in Interventional
Martin Volk1, Ivan Vogt2,3, Marilena Georgiades1,2
1Department of Radiology and Nuclear Medicine, University Hospital Magdeburg and Medical Faculty of Otto-von-Guericke University, 39120 Magdeburg, Germany.
None:
Anthropomorphic CT phantoms are essential training tools for interventional radiology. Given the high technical demands and stringent safety requirements in this field, realistic CT phantoms are vital simulation tools that support effective hands-on training, procedural planning, and risk mitigation. However, commercially available phantom geometries are limited in their scope. This study investigates the use of polyvinyl alcohol (PVA) to fabricate customizable training phantoms. PVA, a non-toxic material, can be processed into PVA cryogels (PVA-C) with tissue-like mechanical properties. We modified PVA-C (10 wt.% PVA) by incorporating various additives to adjust X-ray attenuation and achieve Hounsfield units (HUs) similar to different soft tissues. HU values were measured at X-ray tube voltages of 70, 120, and 150 kV. The inclusion of barium sulfate (e.g., U = 120 kV; 0.1-2 wt.%: 33.29 ± 5.45-323.72 ± 12.64 HU) and iohexol (e.g., U = 120 kV; 0.1-2 wt.%: 26.05 ± 4.74-161.99 ± 5.69 HU) significantly increased HU values. Iohexol produced more homogeneous HU distributions than barium sulfate and cellulose derivatives, with the latter having air gaps and inconsistencies. The tested formulations encompassed a wide range of soft tissue densities, with HU values varying significantly across the energy range (p < 0.001). While cellulose derivatives showed variable HU modulation, their primary role appears to be in modifying phantom texture and morphology rather than precise attenuation control. In conclusion, PVA-C demonstrates strong potential for use in interventional radiology training phantoms. Further studies may enhance phantom realism by replicating tissue textures, for example, through the incorporation of cellulose-based substances.
More Related Videos
09:32Manufacturing Abdominal Aorta Hydrogel Tissue-Mimicking Phantoms for Ultrasound Elastography Validation
Published on: September 19, 2018
08:41Patient-Specific Polyvinyl Alcohol Phantom Fabrication with Ultrasound and X-Ray Contrast for Brain Tumor Surgery Planning
Published on: July 14, 2020
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Radiological Investigation I: X-ray and CT
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Imaging Studies III: Computed Tomography