None:
Introduction: With being introduced just over a century ago, laparoscopic surgery has become more popular than open. Although a steep learning curve is associated, a plethora of simulators, assessments and courses are available to master laparoscopic skills. However, despite a surgeon's expertise, it can be limited by the camera handler. Very little camera navigation training is provided. The aim of this study is to validate a homemade 0 and 30 deg; laparoscope and laparoscopic camera navigation models. Methods: Homemade laparoscope and various camera navigation models were created. 18 participants with no previous camera handling experience or training were recruited. A brief introduction was provided on the study purpose and tasks. They performed 3 tasks on the 0 deg; laparoscope and model (camera navigation, in line orientation and opposite line orientation) and 30 laparoscope and model (camera navigation). Participants were then asked to answer face-content validation questionnaires for both the laparoscopes and models. Results: The cost of the 0 deg; laparoscope came to 25 pounds and the 30 deg; laparoscope was 20 pounds. In the face and content validity questionnaire, the lowest average score of 7.5 was achieved for how realistic it seemed. Of the models designed for camera navigation, model 5 was used with 0 deg; and model 7 was used with 30 deg;. From the questionnaire, the lowest average score of 6.9 was achieved for how realistic the models seemed. For the 0 deg; camera navigation task, the group average of both attempts was 267 seconds. As expected, in line orientation (61 seconds) was completed quicker than opposite line (151 seconds). For 30 deg; camera navigation, the group average time taken was 134 seconds. Conclusion and future recommendations: The homemade laparoscope has proven to be inexpensive and from the exercises carried out by the participants, it is evident the models are effective. The laparoscopic models came to 2760 poubds. Improvements can be made to make them more effective and inexpensive. Subjective assessments should be looked into to see if they can be made objective. It will be interesting to assess participants again after 3-6 months. A follow up study with more participants would be recommended and also a constructive validity with novices, intermediates and experts.
More Related Videos
10:23Technical Approach for Infrared Tracking for Soft Tissue Navigation with a Holographic Head-Mounted Display and Preclinical Validation
Published on: September 2, 2025
05:12Robotized Testing of Camera Positions to Determine Ideal Configuration for Stereo 3D Visualization of Open-Heart Surgery
Published on: August 12, 2021
Related Concept Videos
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and...
Endoscopic Procedures IV: Sigmoidoscopy and Laproscopy
Sigmoidoscopy
Sigmoidoscopy is a diagnostic procedure that uses a flexible sigmoidoscope equipped with a light source and camera to examine the rectum and sigmoid colon. The procedure involves inserting the tube through the anus...