Startling C Behavior in Mo-Free Steel Atom Probe Tomography Volumes.
William Mottay1, Jeremy Landes1,2, Alain Portavoce1
1CNRS, IM2NP, Aix Marseille Université, Campus de Saint-Jérôme, Avenue Escadrille Normandie Niemen, Case 142, Marseille 13397, France.
Carbon segregation at dislocations in steel is only observed with molybdenum co-segregation. This study suggests atom probe tomography (APT) may inaccurately measure carbon in iron due to dislocations leaving samples during analysis.
Area of Science:
- Materials Science
- Metallurgy
- Analytical Chemistry
Background:
- Atom probe tomography (APT) is a key technique for analyzing solute atom segregation at crystalline defects.
- Understanding solute segregation in industrial steels is crucial for material properties and performance.
Purpose of the Study:
- To investigate unexpected observations of carbon (C) segregation at dislocations in industrial steel grades using APT.
- To determine the influence of other elements, specifically molybdenum (Mo), on C segregation at dislocations.
- To assess the accuracy of APT measurements for carbon in iron under specific conditions.
Main Methods:
- Atom probe tomography (APT) was used to analyze solute atom distribution in steel samples.
- Transmission electron microscopy (TEM) was employed for correlative analysis of APT tips.
- Statistical analysis of carbon composition in APT volumes from molybdenum-free steels was performed.
Main Results:
- Carbon segregation at dislocations was exclusively observed in the presence of molybdenum co-segregation.
- In molybdenum-free steels, 35% of APT volumes showed carbon content in solid solution five times higher than expected.
- Correlative TEM-APT analysis confirmed the absence of carbon segregation at dislocations without molybdenum.
Conclusions:
- Atom probe tomography measurements of carbon segregation at dislocations in iron may be inaccurate.
- The high electric fields used in APT can cause dislocations to leave samples, potentially leading to erroneous carbon measurements.
- Molybdenum plays a critical role in the observed carbon segregation at dislocations during APT analysis.
Related Concept Videos
Atomic Force Microscopy
The AFM Probe
The probe is regarded as the heart of any AFM setup and comprises the...
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
Atomic Fluorescence Spectroscopy
X-ray Diffraction of Biological Samples
According to Bragg's law, when X-rays strike the sample positioned on a stage, the rays are scattered by the electron clouds around the sample atoms. The X-ray diffraction or scattering is caused by constructive interference of the X-ray waves that reflect off the internal...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Atomic Nuclei: Magnetic Resonance