Analysis of time delay between non-invasively measured pulse oscillations in cerebral macro- and microcirculation

Marta Hendler1, Arkadiusz Ziółkowski1,2, Tomasz Sozański3

  • 1Department of Biomedical Engineering, Faculty of Fundamental Problems of Technology, Wroclaw University of Science and Technology, Wroclaw, Poland.

PubMed

Objective.Integration of cerebral blood macrocirculation and microcirculation form a crucial aspect of global cerebral blood flow. Our study aimed to investigate time delay between pulse oscillations of cerebral blood flow velocity (FV) and total hemoglobin concentration (tHb) acquired via transcranial Doppler ultrasonography and functional near-infrared spectroscopy, respectively. Additionally, we compared time-related characteristics with cerebral arterial time constant (τ).Approach.The study involved monitoring of FV, tHb, arterial blood pressure and end-tidal CO2(EtCO2) during 5 min of rest (normocapnia) and 5 min of controlled hypercapnia in 36 healthy subjects (age: 24 years,Q1-Q3: 21-27 years, 15 females). Onset time delay (onset TD) was defined as the time offset between onsets of FV and tHb pulses, and time to tHb max (TTM) as a time difference between the FV pulse onset and tHb pulse maximum.τwas calculated as a product of cerebrovascular compliance and resistance. Onset TD and TTM were compared between normocapnia and hypercapnia, and their associations withτwere assessed.Main results.Onset TD was consistently positive (0.075 s,Q1-Q3: 0.065-0.108 s). Onset TD andτwere significantly shorter in hypercapnia (0.075 s vs 0.071 s,p< 0.001; 0.107 s vs 0.099 s,p< 0.001). Changes in onset TD andτbetween normo- and hypercapnia were significantly correlated (RS= 0.452,p< 0.01). TTM was correlated withτin normocapnia (RS= 0.364,p= 0.03), hypercapnia (RS= 0.407,p= 0.01) and in terms of relative changes (RS= 0.421,p= 0.01).Significance.There is a time delay between cerebral macro- and microcirculation, which becomes shorter as the cerebral vasculature dilates in hypercapnia.

Related Concept Videos

Assessment of apical pulse01:17

Assessment of apical pulse

Assessing the Apical Pulse
Assessing the apical pulse is a critical nursing procedure, particularly indicated for:
Assessment of radial pulse01:11

Assessment of radial pulse

Assessment of Radial Pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Assessment of apical radial pulse01:25

Assessment of apical radial pulse

Apical-Radial (A-R) Pulse Assessment
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Assessing Blood pressure using a doppler ultrasound01:19

Assessing Blood pressure using a doppler ultrasound

To obtain accurate blood pressure measurements in clinical settings, especially when traditional methods are insufficient, healthcare professionals utilize the Doppler ultrasound technique. This method uses high-frequency sound waves to detect blood flow within the arteries, which is crucial for patients with conditions that complicate circulatory system assessment.
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Measurement of Blood Pressure01:17

Measurement of Blood Pressure

Assessing blood pressure is a standard procedure executed in virtually all medical environments. The method utilized today was established over a hundred years ago by an innovative Russian doctor, Dr. Nikolai Korotkoff. The soft ticking noise, known as Korotkoff sounds, heard while taking blood pressure readings results from turbulent blood flow within the vessels. The apparatus required for this procedure includes a sphygmomanometer, a blood pressure cuff attached to a gauge, and a stethoscope.
Pulse01:16

Pulse

When the heart pumps blood out, arterial elastic fibers play a crucial role in sustaining a high-pressure gradient. They expand to accommodate the received blood and then recoil - a process known as the pulse that can be either manually palpated or electronically quantified. Despite a reduction in its effect with increased distance from the heart, elements of the pulse's systolic and diastolic components persist, observable even at the arteriole level.
The pulse serves as a clinical indicator...