[Change in corneal refractive power following artificial lens implantation]
Abstract:
Report on the changes in the corneal refractive power of 284 eyes surgically treated for cataract, in which an IOL had been implanted. The mean corneal refractive power of the eyes was 43.31 +/- 1.43 D preoperatively and 43.39 +/- 1.46 D postoperatively (16th week). The postoperative astigmatism of 215 eyes in which a PCL had been implanted after ECCE was not higher than 1.1 +/- 1.1 D in the 16th postoperative week after selected removal of the nylon sutures. This study demonstrates that there is no statistically significant change in the mean corneal refractive power after cataract surgery with IOL implantation.