NMR Spectroscopy: Chemical Shift Overview
Atomic Emission Spectroscopy: Instrumentation
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
You might also read
Articles linked to this work by shared authors, journal, and citation graph.
Matthew B Stone1, Garrett E Granroth2, Daniel M Pajerowski2
1Neutron Scattering Division, Oak Ridge National Laboratory, Oak Ridge, 37831, TN, USA. stonemb@ornl.gov.
Higher flux neutron sources enable automated sample changers for neutron scattering. This study evaluates two sample changers and presents novel sample holder designs for efficient experiments.
10:24Neutron Radiography and Computed Tomography of Biological Systems at the Oak Ridge National Laboratory's High Flux Isotope Reactor
Published on: May 7, 2021
08:48High-Resolution Neutron Spectroscopy to Study Picosecond-Nanosecond Dynamics of Proteins and Hydration Water
Published on: April 28, 2022
Area of Science:
Background:
Neutron scattering facilities serve as indispensable hubs for exploring the fundamental properties of materials at the atomic and molecular levels. Prior research has shown that the evolution of high-flux neutron sources has fundamentally altered the landscape of experimental physics by allowing for faster data collection and higher resolution. These advancements necessitate a parallel evolution in sample environment hardware to prevent instrumentation bottlenecks. Traditional methods of manual sample exchange often result in significant beam time loss, which is increasingly costly as source intensity grows. Thermal chopper spectrometers, which measure energy and momentum transfer, require highly stable and precise positioning systems to ensure data integrity. Despite the rapid progress in source technology, there remains a lack of comprehensive documentation regarding the performance of automated sample changers in these specific high-intensity settings. This absence of evidence motivated the systematic examination of sample changer efficiency and design at the Spallation Neutron Source (SNS).
Purpose Of The Study:
This investigation evaluates the operational efficiency and mechanical design of two specific sample changers used at the thermal chopper spectrometers within the Spallation Neutron Source (SNS). The researchers sought to determine how automated hardware could best support the increased throughput demands of modern high-flux neutron beams. A primary goal involved the development of specialized sample holders that could accommodate diverse specimen types, including both single crystal and powder samples. The study aimed to provide a detailed technical assessment of the Cold Neutron Chopper Spectrometer (CNCS) and its associated sample handling capabilities. By analyzing these systems, the authors intended to establish best practices for the design and operation of automated environments in neutron scattering. The project also focused on the integration of these mechanical systems with the complex control software required for remote experimental management. These efforts were directed toward maximizing the scientific return on investment for the Department of Energy’s large-scale research infrastructure.
Main Methods:
The technical team performed a detailed analysis of two distinct sample changer architectures currently operational at the Spallation Neutron Source (SNS) thermal chopper spectrometers. Researchers used case studies to evaluate the performance of multi-sample holders specifically designed for the Cold Neutron Chopper Spectrometer (CNCS). The investigative process involved monitoring the mechanical reliability and positioning accuracy of the changers during high-flux neutron exposure. Engineers documented the design specifications for holders capable of securing multiple single crystal or powder samples simultaneously. The study employed operational data collected under the UT-Battelle, LLC management contract to assess the efficiency gains provided by automation. The team also examined the structural integrity of the sample holders under the cryogenic and vacuum conditions typical of cold neutron experiments. These evaluations were conducted using the standardized protocols established for the Spallation Neutron Source (SNS) instrument suite.
Main Results:
The implementation of automated sample changers at the Spallation Neutron Source (SNS) thermal chopper spectrometers resulted in a measurable increase in experimental throughput. The design analysis confirmed that the two evaluated sample changers maintained exceptional operational reliability and precision during extended neutron scattering sessions. Case studies involving the Cold Neutron Chopper Spectrometer (CNCS) demonstrated that the new sample holders successfully managed multiple single crystal and powder samples without compromising data quality. The results indicated that the automated systems significantly reduced the time required for sample transitions compared to manual exchange methods. The researchers observed that the higher flux neutron sources were used more effectively, allowing for a greater number of measurements per beam cycle. The technical data showed that the mechanical designs were robust enough to withstand the intense radiation environments of the Spallation Neutron Source (SNS). These findings validate the use of automated sample handling as a standard component for modern neutron scattering instrumentation.
Conclusions:
Automated sample handling systems are essential for the continued advancement of high-flux neutron scattering research. The researchers conclude that the successful integration of sample changers at the Spallation Neutron Source (SNS) provides a scalable model for other neutron facilities worldwide. These findings suggest that the use of multi-sample holders for both single crystal and powder specimens can significantly broaden the scope of materials science investigations. The study’s authors propose that future instrumentation efforts should prioritize the development of even more versatile sample environments to accommodate a wider range of experimental conditions. The documented improvements in operational efficiency will likely lead to more rapid discoveries in condensed matter physics and chemistry. The results underscore the importance of co-developing source technology and sample environment hardware to maximize scientific output. The researchers anticipate that these design principles will inform the next generation of neutron chopper spectrometers.
According to the study's authors, these changers increase efficiency by reducing downtime between measurements at the Spallation Neutron Source (SNS). By automating the transition between multiple single crystal or powder samples, the system maximizes the use of high-flux neutron beams for continuous data acquisition.
The researchers engineered specialized holders for the Cold Neutron Chopper Spectrometer (CNCS) to manage multiple single crystal or powder samples. This design allows for the simultaneous loading of diverse specimen formats, which is essential for high-throughput experiments at the Spallation Neutron Source (SNS).
The authors used case studies of the Cold Neutron Chopper Spectrometer (CNCS) to demonstrate the practical application of multi-sample holders. This approach revealed how specific mechanical designs could successfully maintain alignment and stability for multiple single crystal specimens in a cold neutron environment.
The study indicates that sample changers must operate reliably within the high-flux environments of thermal chopper spectrometers. The designs are specifically constrained by the need for precision positioning and the ability to withstand the intense radiation levels present at the Spallation Neutron Source (SNS).
The study's authors propose that future efforts should focus on expanding the use of automated sample changers across all instrument suites. They state that these advancements are necessary to fully exploit the capabilities of higher flux neutron sources and enhance overall scientific productivity.