Related Experiment Video
Updated: Jul 10, 2026

Lung CT Segmentation to Identify Consolidations and Ground Glass Areas for Quantitative Assesment of SARS-CoV Pneumonia
Published on: December 19, 2020
Artificial intelligence as an independent reader of risk-dominant lung nodules: influence of CT reconstruction
Yifei Mao1,2, Marjolein A Heuvelmans1,2,3, Marcel van Tuinen4
1Department of Epidemiology, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands.
Objectives:
To assess the impact of reconstruction parameters on AI's performance in detecting and classifying risk-dominant nodules in a baseline low-dose CT (LDCT) screening among a Chinese general population.
Materials And Methods:
Baseline LDCT scans from 300 consecutive participants in the Netherlands and China Big-3 (NELCIN-B3) trial were included. AI analyzed each scan reconstructed with four settings: 1 mm/0.7 mm thickness/interval with medium-soft and hard kernels (D45f/1 mm, B80f/1 mm) and 2 mm/1 mm with soft and medium-soft kernels (B30f/2 mm, D45f/2 mm). Reading results from consensus read by two radiologists served as reference standard. At scan level, inter-reader agreement between AI and reference standard, sensitivity, and specificity in determining the presence of a risk-dominant nodule were evaluated. For reference-standard risk-dominant nodules, nodule detection rate, and agreement in nodule type classification between AI and reference standard were assessed.
Results:
AI-D45f/1 mm demonstrated a significantly higher sensitivity than AI-B80f/1 mm in determining the presence of a risk-dominant nodule per scan (77.5% vs. 31.5%, p < 0.0001). For reference-standard risk-dominant nodules (111/300, 37.0%), kernel variations (AI-D45f/1 mm vs. AI-B80f/1 mm) did not significantly affect AI's nodule detection rate (87.4% vs. 82.0%, p = 0.26) but substantially influenced the agreement in nodule type classification between AI and reference standard (87.7% [50/57] vs. 17.7% [11/62], p < 0.0001). Change in thickness/interval (AI-D45f/1 mm vs. AI-D45f/2 mm) had no substantial influence on any of AI's performance (p > 0.05).
Conclusion:
Variations in reconstruction kernels significantly affected AI's performance in risk-dominant nodule type classification, but not nodule detection. Ensuring consistency with radiologist-preferred kernels significantly improved agreement in nodule type classification and may help integrate AI more smoothly into clinical workflows.
Key Points:
Question Patient management in lung cancer screening depends on the risk-dominant nodule, yet no prior studies have assessed the impact of reconstruction parameters on AI performance for these nodules. Findings The difference between reconstruction kernels (AI-D45f/1 mm vs. AI-B80f/1 mm, or AI-B30f/2 mm vs. AI-D45f/2 mm) significantly affected AI's performance in risk-dominant nodule type classification, but not nodule detection. Clinical relevance The use of kernel for AI consistent with radiologist's choice is likely to improve the overall performance of AI-based CAD systems as an independent reader and support greater clinical acceptance and integration of AI tools into routine practice.
More Related Videos
Related Concept Videos
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies for Cardiovascular System V: CT

