Single photon γ-ray imaging with high energy and spatial resolution perovskite semiconductor for nuclear medicine
Nannan Shen1, Xuchang He1, Tingting Gao1
1State Key Laboratory of Radiation Medicine and Protection, School of Radiation Medicine and Protection and Collaborative Innovation Center of Radiation Medicine of Jiangsu Higher Education Institutions, Soochow University, Suzhou, China.
Abstract:
Integrating semiconductor detectors with high energy and spatial resolution is vital for advancing nuclear medicine imaging. Perovskite semiconductors afford unprecedented opportunity for reshaping radiation detection technologies. Nevertheless, perovskite semiconductors have yet to prove their ability in single photon γ-ray imaging, which is essential for enabling nuclear medicine imaging. Herein, we present a pioneering approach to develop high resolution perovskite CsPbBr3 detectors with pixelated configuration capable of imaging single γ-ray photons for nuclear medicine applications. Eliminating charge transport losses at the surface results in exceptional performance uniformity and long-term device stability, which confers near-unity charge collection efficiency and enhanced spectral resolving capabilities. Record energy resolutions are achieved as 2.5% at 141 keV and 1.0% at 662 keV. Single photon imaging with single point and line 99mTc γ-ray sources showcases the high sensitivity of 0.13%~0.21% cps/Bq. Phantom imaging distinctly delineates individual column sources spaced 7 mm apart, indicative of an impressive spatial resolution of 3.2 mm. These findings lay the groundwork for integrating perovskite detectors into nuclear medicine γ-ray imaging systems, offering a balance of cost-effectiveness and superior performance.
More Related Videos
10:24Neutron Radiography and Computed Tomography of Biological Systems at the Oak Ridge National Laboratory's High Flux Isotope Reactor
Published on: May 7, 2021
14:19A Basic Positron Emission Tomography System Constructed to Locate a Radioactive Source in a Bi-dimensional Space
Published on: February 1, 2016
Related Concept Videos
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
X-ray Imaging