Related Experiment Video
Updated: Sep 9, 2025

Magnetic Resonance Imaging of Multiple Sclerosis at 7.0 Tesla
Published on: February 19, 2021
Comparison of Low-Rank Denoising Methods for Dynamic Deuterium MRSI at 7 T
Anna Duguid1, Fabian Niess1, Wolfgang Bogner1,2
1High Field MR Center, Department for Biomedical Imaging and Image-Guided Therapy, Medical University of Vienna, Vienna, Austria.
None:
Dynamic deuterium (2H)-MRSI enables mapping of metabolic fluxes in vivo, but its sensitivity is hampered by the low 2H gyromagnetic ratio and 2H-labelled metabolite concentrations. Low-rank denoising can enhance MRSI sensitivity by separating signal from noise. Several methods have been proposed, but the optimal approach for dynamic 2H-MRSI remains unclear. This work compares six low-rank denoising methods for dynamic 2H-MRSI: four variations of spatiospectral partial separability (PS)-Global PS, Local PS, Stacked PS and SPectral and temporal INtegration for SVD (SPIN-SVD)-as well as global-local higher order singular value decomposition (GL-HOSVD) and tensor Marchenko-Pastur principal component analysis (tMPPCA). Performance was evaluated using realistic 2H-MRSI brain simulations across a range of noise and B0 inhomogeneity levels, including a lesion model featuring focal metabolic alteration, and in vivo data. For simulations at the in vivo SNR and B0 level, the concentration root-mean-square errors (RMSE) of the fitted metabolite maps against gold standard maps were reduced by 29.3%, 24.4%, 20.2%, 33.4%, 23.5% and 21.9% following denoising with Global PS, Local PS, Stacked PS, SPIN-SVD, GL-HOSVD and tMPPCA, respectively. Across all simulated noise levels and all but the highest B0 inhomogeneity level, SPIN-SVD achieved the lowest concentration RMSE and best preserved spatial distributions of 2H-labelled water (HDO) and lactate (Lac), including lesion-associated changes. While Global PS and Stacked PS reduced noise variance, they failed to preserve signal variations in simulated and in vivo data. SPIN-SVD, GL-HOSVD and tMPPCA reduced noise in vivo while maintaining spatial and temporal metabolite variations. GL-HOSVD and tMPPCA performed similarly, with tMPPCA preferred for its computational efficiency. Both SPIN-SVD and tMPPCA are suitable for denoising dynamic 2H-MRSI, with SPIN-SVD preferable for clinical applications owing to its simple implementation and superior preservation of local metabolic alterations, and tMPPCA better suited for absolute quantification of very low SNR metabolites.
More Related Videos
Related Concept Videos
¹³C NMR: Distortionless Enhancement by Polarization Transfer (DEPT)
¹³C NMR: ¹H–¹³C Decoupling
A broadband decoupling technique is used to simplify these complex, sometimes overlapping, signals. Broadband decoupling relies on a...
¹H NMR of Labile Protons: Deuterium (²H) Substitution
Chemical Shift: Internal References and Solvent Effects
The internal reference compound generally used in NMR spectroscopy is tetramethylsilane (TMS). TMS is preferred because it is chemically inert, soluble in NMR solvents, and easily removable. Also, the highly shielded methyl protons in TMS yield an intense...
2D NMR: Overview of Homonuclear Correlation Techniques
COSY90 is the standard two-dimensional (2D) COSY experiment that...
Double Resonance Techniques: Overview
Spin decoupling is usually achieved by...