Alterations in diaphragmatic activity preceding and during intermittent hypoxaemia events in preterm infants
Ruud W van Leuteren1,2, Lieke A P Arts3,4, Fabio A Blom3,2
1Department of Neonatology, Emma Children's Hospital, Amsterdam UMC, University of Amsterdam, Amsterdam, The Netherlands r.w.vanleuteren@amsterdamumc.nl.
Objective:
To assess the activity of the diaphragm using electromyography (dEMG) prior and during apnoea-induced intermittent hypoxaemia (IH) events in preterm infants DESIGN: A single-centre observational study.
Setting:
Neonatal intensive care unit.
Patients:
Preterm infants (<32 weeks of gestation) experiencing IH events with a frequency of >1/hour METHODS: Heart rate, oxygen saturation (SpO2) and dEMG were measured for 24 hours. dEMG data were processed for all IH events resulting in a SpO2<80%. Events were scored by two reviewers as central, obstructive or mixed. Subsequently, minimum (dEMGmin) and maximum (dEMGmax) diaphragmatic activity were calculated in three time periods (5-1 min prior, 1 min prior and during the desaturation) for each event. The dEMG activity over time was also compared between the different apnoea types.
Results:
20 infants (gestational age 27.6±1.3 weeks) were included. A total of 591 IH events were used for analysis of which 88 (14.9%), 239 (40.4%) and 264 (44.7%) were scored as central, obstructive and mixed, respectively. In the 1 min before the actual IH, dEMGmax and dEMGmin dropped for central and increased for obstructive events. Central and obstructive events also differed during the actual event (dEMGmin 6.1 vs 8.4 µV and dEMGmax 9.4 vs 13.3 µV, both p<0.001 for central vs obstructive events). Mixed events did not show a distinct dEMG pattern.
Conclusion:
dEMG can detect and characterise central and obstructive apnoea before the IH event occurs, which supports development of automated detection and classification of apnoea events.
Related Concept Videos
Alterations in Respiration II
In Biot's breathing, the respiratory rate and depth are irregular, alternating between periods of deep gasping and apnea. Common causes...
Pulmonary Cycle: Exhalation
Acute Respiratory Failure-II
The underlying physiological abnormalities that contribute to hypoxemic respiratory failure include:
Acute Respiratory Failure-IV
Hyperpnea and Hyperventilation
Respiratory System Abnormal Finding I: Inspection and Percussion
Inspection Findings
During an inspection, several findings may suggest the presence of respiratory distress or disease. Pursed-lip breathing, where exhalation is slowed by...