Establishment of National Diagnostic Reference Levels 2025 for nuclear medicine in Japan
Koichiro Abe1, Shingo Baba2, Reo Etani3
1Department of Radiology, Tokyo Medical University, 6-7-1 Nishishinjuku, Shinjuku-Ku, Tokyo, 160-0023, Japan. k-abe@tokyo-med.ac.jp.
Abstract:
Diagnostic reference levels (DRLs) are practical benchmarks for optimizing patient radiation exposure in medical imaging. In Japan, national DRLs, including those for nuclear medicine together and other radiological procedures, were first established in 2015 and revised in 2020. In this study, we revised the DRL values of nuclear medicine for the establishment of DRLs2025, based on data collected from institutions nationwide throughout Japan. Data were collected via an online survey from facilities performing nuclear medicine procedures, including SPECT, PET, and hybrid CT imaging. Information on dose activity of the administered radiopharmaceuticals and CT parameters (CTDIvol and DLP) were collected. DRL values were determined through analysis of the submitted data, supplemented by panel discussions among experts taking into account the clinical appropriateness of the values and various technological factors. Overall, the newly established DRLs2025 demonstrated a decreasing trend in administered radiopharmaceutical activities, CTDIvol, and DLP compared with the previous surveys. This trend reflects ongoing efforts toward the optimization of radiation exposure and radiopharmaceutical dose reduction, likely driven by the introduction of image reconstruction methods based on newer technologies. However, substantial interfacility variations were observed, particularly in the CT parameters, suggesting disparities in equipment, imaging protocols, and the balance between image quality and radiation dose. The establishment of DRLs2025 underscores continued progress in optimizing radiation exposure in nuclear medicine practice in Japan. Although issues regarding data variability and quality remain, DRLs continue to be a key tool in radiation protection and quality assurance. Ongoing efforts to improve data collection systems and to align procedures with international standards are essential for the future refinement of DRLs.
More Related Videos
09:55Radiosynthesis, Quality Control, and Small Animal Positron Emission Tomography Imaging of 68Ga-Labelled Nano Molecules
Published on: October 4, 2024
09:49A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy PRRT: 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
Published on: April 24, 2020
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Transducer Mechanism: Nuclear Receptors
About 48 different soluble family members of nuclear receptors are identified that can be divided into two main classes:
Nuclear Fission
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Nuclear Localization Signals and Import
Nuclear Power
Nuclear Fuels
Nuclear fuel consists of a fissile isotope, such as uranium-235, which must be present in sufficient quantity to provide a...