Related Experiment Video
Updated: Sep 9, 2025

Cutoff Value of Phase Angle by Bioelectrical Impedance Analysis at Admission as a Prognostic Factor in Patients with Acute Heart Failure
Published on: June 10, 2025
Bioimpedance-Derived Phase Angle Was Associated with Faster Blood Pressure Stabilisation Following Orthostatic
Román Romero Ortuño1,2, Eoin Duggan1,2
1Discipline of Medical Gerontology, School of Medicine, Trinity College Dublin, Ireland.
Abstract:
Phase Angle (PA), derived from bioelectrical impedance analysis, reflects cellular health and may indicate physiological resilience in ageing. We examined the relationship between PA and blood pressure (BP) recovery following an orthostatic challenge in 107 older adults attending a specialist falls clinic. Participants underwent active stand testing with continuous, beat-to-beat BP monitoring over 180 seconds. PA was categorised into tertiles (low, medium, high), and changes in systolic (SBP) and diastolic BP (DBP) were analysed using linear mixed-effects models, adjusted for age, sex, diabetes, hypertension, and cardiovascular and psychotropic medication use. Compared to the low PA tertile, individuals in the medium and high PA tertiles demonstrated faster recovery in both SBP and DBP during the 10-20 second post-stand period (all p < 0.001). No significant differences were observed in recovery between the 20-30 and 30-40 second intervals. Furthermore, participants in the high PA tertile showed, in contrast to the low PA tertile, full mean BP recovery at 40 seconds, with no further upward trend thereafter (p = 0.001 for SBP, p = 0.005 for DBP). PA could be a simple, non-invasive biomarker of dynamic physiological resilience, potentially identifying older adults at increased risk of early orthostatic haemodynamic instability.
More Related Videos
04:05Author Spotlight: Unveiling Prognostic Indicators in Heart Failure - The Role of Phase Angle and Bioelectrical Impedance Analysis
Published on: June 30, 2023
14:09Tilt Testing with Combined Lower Body Negative Pressure: a "Gold Standard" for Measuring Orthostatic Tolerance
Published on: March 21, 2013
Related Concept Videos
Pre-Procedural Guidelines for Assessing Blood Pressure
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Measurement of Blood Pressure
Assessment of blood pressure in brachial artery(two-step method)
Errors occurring during blood pressure monitoring
Several factors...
Assessing Blood pressure in the Leg
Preparation: