Integrated experimental and FLUKA simulation for enhanced radiation safety in open-ceiling radiographic testing
Sung Hoe Heo1, Jaewoong Kim2, Du-Song Kim3
1Department of Emergency and Disaster Management, Graduate School, Inje University, Gimhae 50834, Republic of Korea.
None:
Radiographic testing (RT) is a critical non-destructive testing method for ensuring the structural integrity of pipe welds through quantitative detection of internal defects. However, radiation safety concerns often lead to overly conservative regulatory restrictions, particularly affecting open-ceiling radiographic facilities through excessive limitations on irradiation direction and shielding, thereby reducing productivity. This study conducted quantitative analyses and on-site radiation measurements under varying irradiation angles and shielding conditions in an open-ceiling RT facility located within a pipe fabrication workshop. Radiation dose distributions were estimated using Monte Carlo simulations with the FLUKA code, and results were validated against experimental measurements through relative error analysis. Under the most stringent upward irradiation condition, compliance with the public dose rate limit of 1µSv h-1was successfully achieved using a tungsten collimator and minimal lead shielding. These results underscore the importance of adopting scientifically justified evaluation frameworks for radiation safety in non-enclosed RT facilities. The proposed approach demonstrates that achieving both radiation safety and operational flexibility is feasible without requiring fully enclosed shielding structures, thereby significantly enhancing inspection efficiency and industrial productivity.
More Related Videos
09:18Laser-heating and Radiance Spectrometry for the Study of Nuclear Materials in Conditions Simulating a Nuclear Power Plant Accident
Published on: December 14, 2017
06:28Visualization of Low-Level Gamma Radiation Sources Using a Low-Cost, High-Sensitivity, Omnidirectional Compton Camera
Published on: January 30, 2020
Related Concept Videos
Radiation: Applications
The average...
Absorption of Radiation
Radiological Investigation I: X-ray and CT
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...