Estimation of mean glandular dose using breast-equivalent phantoms: a foundational study for regional DRL formulation
Dr Saravana Kumar A1, Sudhir Kumar2,3, K N Govindarajan1
1Department of Medical Physics, PSG Institute of Medical Sciences Research & Hospitals, Coimbatore 641 004, Tamil Nadu, India.
Abstract:
The objective of this foundational study is to support the development of regional diagnostic reference levels (DRLs) for mammography screening in India by estimating mean glandular dose (MGD) using appropriate breast-equivalent phantoms across computed mammography (CR), digital mammography (DR), and digital breast tomosynthesis (DBT) systems. Additionally, system-displayed MGD values were compared with calculated MGD values to evaluate their accuracy for routine clinical use. A total of 5000 mammographic views were collected across CR, DR, and DBT units. For each unit and phantom thickness, ten entrance surface air kerma (ESAK) measurements were performed under clinical settings using a calibrated solid-state dosimeter (AccuGold+, Radcal, USA). Breast-equivalent slab phantoms (Sun Nuclear, USA), ranging from 30 mm to 90 mm, were used to simulate varying glandular compositions. Standard American College of Radiology and DBT phantoms were employed to ensure consistent imaging conditions. MGDs were derived from ESAK values using IAEA recommended conversion factors. For DR and DBT systems, calculated MGDs were compared with system displayed values. The 75th percentile MGDs for each phantom thickness were used to propose regional DRLs, in line with ICRP Publication 135 and IAEA Human Health Report No. 77. At the standard 60 mm compressed breast thickness, the 75th percentile MGDs were found to be 2.58 ± 0.38 mGy (CR), 1.68 ± 0.86 mGy (DR), and 2.66 ± 0.78 mGy (DBT). System-displayed MGDs in DR and DBT were observed to be 13%-17% higher than calculated values. This study presents a scalable, reproducible framework for establishing regional, thickness-specific DRLs in India, supporting dose optimisation and quality assurance in mammography practice.
More Related Videos
06:20Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
07:57Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
Published on: March 24, 2022
Related Concept Videos
Measurement of Bioavailability: Pharmacodynamic Methods
Drug Dosing in Renal Diseases: Estimation of Glomerular Filtration Rate Based on Serum Creatinine Concentration