Related Experiment Video
Updated: Sep 9, 2025

Measuring Carbon-based Contaminant Mineralization Using Combined CO2 Flux and Radiocarbon Analyses
Published on: October 21, 2016
Total alkalinity measurements in small samples: methods based on CO2 equilibration and spectrophotometric pH
Kalla L Fleger1, Xuewu Liu1, William M Berelson2
1College of Marine Science, University of South Florida, St. Petersburg, USA.
Background:
Total alkalinity (AT) is a fundamental parameter in understanding the oceanic cycling of carbon dioxide (CO2). Measurements of the AT of natural waters are typically obtained through single- or multi-step titrations using a strong acid, with the endpoint pH determined via potentiometry or spectrophotometry. Conventional AT determinations are labor-intensive and require precise knowledge of the sample's weight or volume. Equilibration with CO2 gas, with or without a membrane, can simplify the procedure and reduce the required sample volume while maintaining high precision.
Results:
Several spectrophotometric AT methodologies involving CO2 gas as a titrant are presented: stopped-flow equilibration across a liquid core waveguide (LCW), continuous equilibration using gas-permeable silicone tubing, and direct bubbling with CO2 gas for measurements of small samples. Alkalinity determinations from CO2 equilibration are based on a simple linear relationship between AT, pCO2, and spectrophotometric pH. Incorporating an empirically derived, temperature-dependent calibration constant, E(T), eliminates the need for precise CO2 concentrations. Equilibration-based AT measurements demonstrated high precision (±1.0-2.0 μmol kg-1) and were in strong agreement with standard titration methods (±2.0 μmol kg-1). Novel spectrophotometric instrumentation is introduced, named the Minimal Volume Multiparameter Inorganic Carbon Analyzer (MVMICA), capable of precise pHT (±0.002) and AT measurements with volumes ∼1.0 mL. The accuracy of MVMICA over a wide range of conditions makes it invaluable for assessing carbonate chemistry in aquatic systems using limited available sample volumes.
Significance:
The three methods presented in this paper offer flexible configurations, each adaptable for specific applications. Membrane equilibrations using Teflon AF 2400 LCW or silicone tubing are appropriate for automated analysis of waters, with potential for in situ AT determinations. Equilibration of samples across a silicone membrane facilitates rapid, continuous measurements. Alternatively, direct equilibration without a membrane enables analyses of samples as small as 0.50 mL.
Related Concept Videos
Titration of Polyprotic Base with a Strong Acid
Diagnosing Acidosis and Alkalosis
First, the pH level is assessed to determine whether the blood pH is normal (7.35–7.45), low (acidosis), or high (alkalosis).
Next, the PCO2 and...
Titration of a Weak Acid with a Weak Base
As a result, there is no simple...
EDTA: Indirect and Alkalimetric Titration
Titration Calculations: Weak Acid - Strong Base
For the titration of 25.00 mL of 0.100 M CH3CO2H with 0.100 M NaOH, the reaction can be represented as:
Acid–Base Titration: Overview