Dynamic Lissajous patterns for real time identification and localization of power quality disturbance

Pampa Sinha1, Snehalika Snehalika2, Ranjith Kumar Gatla3

  • 1School of Electrical Engineering, KIIT, Bhubaneswar, 751024, India. pampa.sinhafel@kiit.ac.in.

Scientific Reports
|September 5, 2025
PubMed
Abstract

Related Concept Videos

Energy and Power Signals01:17

Energy and Power Signals

In an electrical system with a resistor, voltage and current signals facilitate the measurement of power and energy across the resistor. For a continuous-time signal, the total energy over a time interval is defined as the integral of the square of the signal's magnitude over that interval. Mathematically, this is expressed as:
568
Power Factor Correction01:20

Power Factor Correction

The power transmission to a factory involves the transfer of apparent power, a combination of active and reactive power. The power factor measures how effectively electrical power is converted into useful work output. The ratio of the real power (KW) that does the work to the apparent power (KVA) supplied to the circuit.
259
Power System Three-Phase Short Circuits01:21

Power System Three-Phase Short Circuits

Determining the subtransient fault current in a power system involves representing transformers by their leakage reactances, transmission lines by their equivalent series reactances, and synchronous machines as constant voltage sources behind their subtransient reactances. In this analysis, certain elements are excluded, such as winding resistances, series resistances, shunt admittances, delta-Y phase shifts, armature resistance, saturation, saliency, non-rotating impedance loads, and small...
148
Fast Decoupled and DC Powerflow01:24

Fast Decoupled and DC Powerflow

The fast decoupled power flow method addresses contingencies in power system operations, such as generator outages or transmission line failures. This method provides quick power flow solutions, essential for real-time system adjustments. Fast decoupled power flow algorithms simplify the Jacobian matrix by neglecting certain elements, leading to two sets of decoupled equations:
275
Power Factor01:11

Power Factor

The power factor is defined as the ratio of average (or active) power to apparent power, as illustrated by the relation
452
Maximum Power Flow and Line Loadability01:23

Maximum Power Flow and Line Loadability

The maximum power flow for lossy transmission lines is derived using ABCD parameters in phasor form. These parameters create a matrix relationship between the sending-end and receiving-end voltages and currents, allowing the determination of the receiving-end current. This relationship facilitates calculating the complex power delivered to the receiving end, from which real and reactive power components are derived.
178