Related Experiment Video
Updated: May 6, 2026

An Anesthesia, Surgery, and Harvest Method for the Evaluation of Transpedicular Screws Using an In Vivo Porcine Lumbar Spine Model
Published on: May 31, 2017
On the biomechanics of a novel L5-S1 posterior fixation system: A finite element study
Aline F Gouveia1,2, Paulo R Fernandes1, André P G Castro1,3
1IDMEC, Instituto Superior Técnico, Universidade de Lisboa, Lisbon, Portugal.
Abstract:
Low back pain is estimated to affect more than 70% of the population. Recently, interspinous posterior devices are gaining attention as a less invasive alternative to the traditional pedicle screw systems. However, since most of these devices are not suitable for the L5-S1 segment, the goals for this study are to design a tailored fixation system for the L5-S1 level and to study its effects on the degenerated spine. To that end, a finite element model of the L4-S1 spinal segment was developed, considering three different clinical stages (healthy, mildly degenerated and moderately degenerated). The instrumented spine was then simulated in short-term and long-term post-surgery stages, combined with the degenerated conditions. This system was able to effectively reduce the movement of the implanted segment by up to 96% in flexion and extension, 80% in lateral bending and 83% in axial rotation. In what concerns to the maximum principal stress in the disc region, the implanted model has shown a reduction of 80% in flexion, 76% in extension and 78% in lateral bending. These are promising outputs in terms of reducing the movement and the stress levels of the instrumented spine in all directions of motion, particularly flexion and extension, even if the device would require further experimental, computational and clinical studies. Although the mobility of the L4-L5 segment was not altered in the simulations, minor changes in the stress distribution were found in this segment, suggesting a reduced probability of adjacent disc disease with this system.
More Related Videos
06:41A Minimally Invasive Model to Analyze Endochondral Fracture Healing in Mice Under Standardized Biomechanical Conditions
Published on: March 22, 2018
08:20A Reliable and Reproducible Critical-Sized Segmental Femoral Defect Model in Rats Stabilized with a Custom External Fixator
Published on: March 24, 2019
Related Concept Videos
Two-Dimensional Force System
Three-Dimensional Force System
System of Forces and Couples
The principle of transmissibility plays a crucial role in this process. According to...
Simplification of a Force and Couple System I
Simplification of a Force and Couple System: II
One-Degree-of-Freedom System
A one-degree-of-freedom system is defined by an independent variable that determines its state and behavior. One example of a one-degree-of-freedom system is a simple harmonic oscillator, such as a...