Related Experiment Video
Updated: Jan 18, 2026

Invasive Hemodynamic Monitoring of Aortic and Pulmonary Artery Hemodynamics in a Large Animal Model of ARDS
Published on: November 26, 2018
Effect of ECMO Flow Variations on Pulmonary Capillary Wedge Pressure in Patients With Cardiogenic Shock
Ouriel Saura1, Guillaume Hékimian1, Grégoire Del Marmol1
1Service de Médecine Intensive-Réanimation, Institut de Cardiologie, Assistance Publique-Hôpitaux de Paris (AP-HP), Sorbonne Université, Hôpital Pitié-Salpêtrière, Paris, France; Sorbonne Université, INSERM, UMRS_1166-ICAN, Institute of Cardiometabolism and Nutrition, Paris, France.
Background:
The hemodynamic effects of femoro-femoral venoarterial (VA) extracorporeal membrane oxygenation (ECMO) on pulmonary capillary wedge pressure (PCWP) remain poorly defined. High ECMO flow is believed to increase PCWP and the risk of pulmonary edema; yet, supporting in vivo physiological data are lacking.
Objectives:
The purpose of this study was to evaluate the impact of incremental femoro-femoral VA-ECMO flow variations on PCWP, hemodynamic, and echocardiographic parameters in patients with cardiogenic shock during the early phase of VA-ECMO support, after stabilization.
Methods:
This prospective, single-center interventional study was conducted at Pitié-Salpêtrière Hospital, Paris, France. The ECMO-Flow trial consisted of stepwise VA-ECMO flow variations from 2 to 4 L/min in 0.5-L/min increments. Hemodynamic assessment included pulmonary artery catheter measurements, transthoracic echocardiography, and blood gas analyses.
Results:
A total of 80 patients were included. At baseline, 27 patients (34%) had PCWP ≥18 mm Hg. Left ventricular (LV) dilation, mitral regurgitation, elevated central venous pressure (CVP), and preserved right ventricular (RV) function were associated with higher baseline PCWP. During the ECMO-Flow trial, PCWP decreased in 29 patients (36%), remained stable in 46 (58%), and increased in only 5 (6%), despite a concomitant rise in LV afterload. CVP significantly decreased, while RV afterload remained unchanged. Indexed stroke volume decreased and myocardial work remained stable despite an increase in LV afterload. Throughout the ECMO-flow trial, a significant PCWP decrease was observed in patients with better baseline LV and RV function and lower CVP.
Conclusions:
As VA-ECMO flow increases, the expected rise in PCWP caused by afterload elevation appears to be counterbalanced by a reduction in RV preload, resulting in a neutral effect in most patients, a significant PCWP decrease in approximately one-third, and an only infrequent increase.
More Related Videos
03:40Point-of-Care Ultrasound for Peripheral Veno-Arterial Extracorporeal Membrane Oxygenation Without Left Ventricular Venting
Published on: January 17, 2025
06:10Utilizing Percutaneous Ventricular Assist Devices in Acute Myocardial Infarction Complicated by Cardiogenic Shock
Published on: June 12, 2021
Related Concept Videos
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Measurement of Blood Pressure
Blood Pressure Imbalances and Circulatory Shock
Blood Pressure: Hypertension and Hypotension
Normal blood pressure is 120/80 mm Hg. Elevated blood pressure is 120-129/under 80 mm Hg. Hypertension, warranting treatment at 130/80 mm Hg, is often asymptomatic and can lead to severe cardiovascular events, aneurysms, peripheral arterial disease, chronic renal disease, or cardiac...
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart...