Published on: September 8, 2016
Therapeutic Drug Monitoring Using a Poly(N-isopropylacrylamide) Hydrogel-Modified Bead-Packed Column with an
Kenichi Nagase1,2, Maho Kuwabara2, Hideko Kanazawa2
1Graduate School of Biomedical and Health Sciences, Hiroshima University, 1-2-3 Kasumi, Minami-ku, Hiroshima 734-8553, Japan.
This study introduces a novel chromatography column for therapeutic drug monitoring (TDM). The temperature-sensitive column enables solvent-free drug concentration analysis in serum, simplifying TDM procedures.
Area of Science:
- Analytical Chemistry
- Materials Science
- Biomedical Engineering
Background:
- Therapeutic drug monitoring (TDM) is crucial for optimizing drug efficacy and safety.
- Current TDM methods often rely on organic solvents and extensive sample preparation.
- A need exists for simpler, safer, and more efficient TDM techniques.
Purpose of the Study:
- To develop and evaluate a novel chromatography column for TDM.
- To enable TDM using an aqueous mobile phase and temperature-sensitive materials.
- To eliminate the need for organic solvents and complex sample preparation in TDM.
Main Methods:
- Silica beads were modified with poly(N-isopropylacrylamide) (PNIPAAm) hydrogels via condensation and radical polymerization.
- A chromatography column was packed with the modified silica beads.
- Drug elution behavior was studied using an aqueous mobile phase at varying temperatures.
- Separation of model serum samples containing drugs and proteins was performed.
- Drug concentrations were quantified using calibration curves.
Main Results:
- The PNIPAAm-modified silica bead column demonstrated temperature sensitivity.
- Successful separation of serum proteins and model drugs was achieved at 30°C using an aqueous mobile phase.
- The column enabled drug concentration quantification without organic solvents.
- The method showed potential for simplified sample preparation.
Conclusions:
- The engineered chromatography column offers a promising advancement for therapeutic drug monitoring.
- This temperature-sensitive system provides a safe, straightforward, and solvent-free approach to TDM.
- The developed method simplifies TDM by reducing reliance on organic solvents and complex sample preparation.