Related Experiment Video
Updated: Aug 11, 2026

Shrinkage of Dental Composite in Simulated Cavity Measured with Digital Image Correlation
Published on: July 21, 2014
In Vitro Evaluation of Time-Dependent Linear Dimensional Changes in Four Interocclusal Recording Materials
Vandana Rai1, Mohammed Aleemuddin2, Kanimozhi Kulasekaran3
1Prosthodontics, Crown and Bridge, Sree Balaji Dental College and Hospital, Chennai, IND.
Polyvinylsiloxane materials offer superior dimensional accuracy and stability for occlusal records. Minimizing storage time after recording is crucial for reliable prosthodontic outcomes.
Area of Science:
- Dental Materials Science
- Prosthodontics
- Biomaterials Engineering
Background:
- Accurate occlusal records are fundamental for successful prosthodontic restorations.
- Dimensional stability of interocclusal recording materials is critical to prevent inaccuracies in the final prosthesis.
- Previous studies have shown variability in the dimensional stability of different classes of impression materials.
Purpose of the Study:
- To compare the linear dimensional and weight changes of four interocclusal recording materials: polyether (Ramitec), two polyvinylsiloxane variants (O-Bite, Jet Bite), and dimethacrylate (LuxaBite).
- To evaluate the effectiveness of these materials in maintaining accurate occlusal records over time (1 hour, 24 hours, 1 week).
Main Methods:
- Twenty samples of each material were prepared and subjected to a 500-g weight.
- Dimensional changes were measured using a stereomicroscope.
- Weight changes were assessed using an electronic scale at 1-hour, 24-hour, and 1-week intervals.
- Statistical analyses included one-way ANOVA and repeated measures ANOVA.
Main Results:
- Polyvinylsiloxane (Jet Bite) exhibited the highest dimensional stability with minimal changes (0.49% at 1 hour, 0.52% at 24 hours, 0.50% at 1 week).
- Another polyvinylsiloxane (O-Bite) showed higher dimensional changes (1.13% at 1 hour, 1.51% at 24 hours, 1.50% at 1 week).
- Polyether (Ramitec) had significant initial variation (3% at 1 hour), while dimethacrylate (LuxaBite) showed expansion followed by contraction linked to polymerization and weight loss.
Conclusions:
- Polyvinylsiloxane materials demonstrated superior dimensional accuracy and stability among the tested materials.
- Timely mounting of casts after recording significantly improves accuracy, emphasizing the importance of minimizing storage time.
- A strong correlation exists between weight changes and dimensional alterations across all materials, impacting clinical reliability.
More Related Videos
07:04Confocal Time Lapse Imaging as an Efficient Method for the Cytocompatibility Evaluation of Dental Composites
Published on: November 9, 2014
07:42Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024
Related Concept Videos
Distance Measurements by Taping
Distance Corrections