Development of a gamma-gamma angular correlation digital instrumentation at LNE-LNHB
Sylvain Leblond1, Christophe Bobin1
1Université Paris-Saclay, CEA, List, Laboratoire National Henri Becquerel (LNE-LNHB), Palaiseau, F-91120, France.
Abstract:
The LNE-LNHB has recently developed a coincidence instrumentation to take advantage of the latest developments in fast digital acquisition. The performances of the new setup have been tested using two LaBr3 scintillation detectors to investigate gamma-gamma angular correlation in 60Co decay. For that purpose, a specific goniometer based on a simple design was developed. The data collection using a list-mode data acquisition with a CAEN DT5730 digitizer was carried out over a period of three months using an 800-kBq 60Co source. The counting analysis was performed taking advantage of the fast decay properties, and good energy resolution, of the two LaBr3 detectors allowing a very strict selection of the coincident gamma events. From this study, the parameters of 60Ni angular correlation were determined to be equal to a2 = 0.1030(31) and a4 = 0.0097(36), respectively. These results are consistent with previously published values. The accuracy obtained is compared to various recent studies and to a reference cryogenic measurement. Prospects for improvement of the experimental setup are discussed.
Related Concept Videos
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Pressure Gauges
Electronic Distance Measuring Instruments
Leveling Equipment