Initial Fire Disposal Technology for Electric Wires: Active Fire Prevention and Extinguishing Concepts

Zhixin Tang1,2, Tianwei Zhang1,2, Hao Liu1,2

  • 1National Engineering Research Center of Fire and Emergency Rescue, China People's Police University, Langfang 065000, Hebei, China.

ACS Omega
|September 15, 2025
PubMed
Abstract

Related Concept Videos

Reclosers and Fuses01:26

Reclosers and Fuses

Automatic circuit reclosers enhance the protection of distribution circuits by interrupting and auto-reclosing an AC circuit according to a preset sequence. They effectively manage temporary faults on overhead distribution lines, often caused by tree limbs or wildlife, by briefly disrupting service to improve overall reliability. However, contact with reclosers or energized broken conductors on the ground can pose serious hazards.
A comprehensive protection scheme for radial distribution...
454
Circuit Breaker and Fuse Selection01:23

Circuit Breaker and Fuse Selection

A circuit breaker is a device engineered to interrupt fault currents and sometimes reclose automatically. When a fault current is detected, the breaker separates the electrical contacts, which generates an arc. This arc is extinguished by methods such as elongation, cooling, or splitting, depending on the breaker's design. Breakers are categorized based on the voltage they operate at and the medium used for arc extinction, such as air, oil, SF6 gas, or vacuum.
In high-voltage systems,...
573
Household Wiring And Electrical Safety01:13

Household Wiring And Electrical Safety

Companies that supply power to most modern households use three conductors, typically called a three-wire line. While one is neutral, the other two are both at 120 V but with opposite polarity, giving a voltage of 240 V between them. With a three-wire line, high-power appliances that require 240 V, such as electric stoves and clothes dryers, are linked between the two hot lines. 120 V appliances can be connected between the neutral and either of the hot lines. The neutral side, which is always...
1.6K
Insulation Coordination01:23

Insulation Coordination

Insulation coordination is the process of matching electric equipment's insulation strength with protective device characteristics to protect the equipment against expected overvoltages. This selection is based on engineering judgment and cost. Equipment can generally withstand short-duration high transient overvoltages, but repeated tests with identical waveforms can yield inconsistent results. As a result, standard impulse voltage waveforms are used for testing, defined by specific times...
552
Faraday's Law01:10

Faraday's Law

Faraday's law state that the induced emf is the negative change in the magnetic flux per unit of time. Any change in the magnetic field or change in the orientation of the area of the coil with respect to the magnetic field induces a voltage (emf). The magnetic flux measures the number of magnetic field lines through a given surface area. Magnetic flux is estimated from the integral of the dot product of the magnetic field vector and the area vector. The negative sign describes the...
5.7K
Design Example: Flow Through a Fire Extinguisher01:12

Design Example: Flow Through a Fire Extinguisher

A fire extinguisher that uses pressurized water relies on fluid dynamics principles to generate a high-velocity stream capable of suppressing flames. The water is stored at a much higher pressure inside the extinguisher than the surrounding atmosphere. This pressure difference forces the water to flow rapidly when the extinguisher is activated, and the behavior of the water as it exits the nozzle can be understood using fundamental equations of fluid dynamics.
The key to understanding how the...
456