From a Voxel to Maps: A Comparative Study of sLASER SVS and 3D-CRT-FID-MRSI at 3 T and 7 T
Zeinab Eftekhari1,2, Korbinian Eckstein2,3, Bernhard Strasser4
1Centre for Advanced Imaging, The University of Queensland, Brisbane, QLD, Australia.
Abstract:
Magnetic resonance spectroscopy (MRS) enables non-invasive assessment of brain metabolites and is commonly implemented using single-voxel spectroscopy (SVS) or magnetic resonance spectroscopic imaging (MRSI). This study directly compares the reproducibility of SVS-based semi-localization by adiabatic selective refocusing (sLASER) and 3D-Concentric Ring Trajectory-based Free Induction Decay MRSI (3D-CRT-FID-MRSI) at 3T and 7T in the same cohort of healthy participants. To explore MRSI's capabilities for regional metabolite quantification and reproducibility assessment, three masking strategies were applied. Additionally, two spatial averaging approaches for MRSI, averaging before vs. after spectral fitting, were evaluated. Coefficients of variation (CV) and voxel-wise correlation analyses were used to assess intra-subject and inter-session reproducibility. Results showed good-to-excellent reproducibility across both techniques, with SVS generally providing lower CVs at 7T, while MRSI outperformed SVS in several metabolites at 3T. MRSI allowed tissue-specific analysis, with lower CVs observed in WM compared to GM, especially at 7T. Although MRSI reproducibility was slightly reduced at 7T likely due to longer scan times and lack of prospective motion correction, the spatial coverage and retrospective region analysis makes it an attractive alternative to SVS for many brain regions. This study demonstrates that both sLASER and CRT-FID-MRSI provide reproducible metabolite measurements at 3T and 7T. The findings highlight MRSI's advantages for retrospective multi-regional and tissue-specific analysis, facilitating its integration into future clinical research.
More Related Videos
10:25Author Spotlight: Integrating High-Resolution Intravital Imaging and MRI to Enhance Stereotactic Body Radiation Therapy Planning
Published on: April 12, 2024
08:36Multi-Tracer Studies of Brain Oxygen and Glucose Metabolism Using a Time-of-Flight Positron Emission Tomography-Computed Tomography Scanner
Published on: June 7, 2024
Related Concept Videos
Imaging Studies III: Computed Tomography
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies IV: Magnetic Resonance Imaging
Imaging Studies for Cardiovascular System IV: CMRI