Open Peri-Implant Distal Radius Fracture Following Previous Treatment With a Dorsal Nail-Plate Device: A Case Report
Abdulai Bangura1, Mubinah Khaleel1, Lasun Oladeji1
1Department of Orthopedic Surgery, University of Missouri School of Medicine, Columbia, USA.
None:
Peri-implant distal radius fractures are rare but are expected to increase in incidence due to the shift from closed reduction and casting to operative fixation. The literature on distal radius peri-implant fractures is limited, with nearly all reported cases involving volar plate osteosynthesis. We report a case of an adult male who sustained a peri-implant distal radius fracture around a previously placed dorsal intramedullary nail-plate device, accompanied by an open ulnar fracture. A healthy 36-year-old right-hand-dominant male experienced this injury following a fall from a motorized scooter. During surgery, the deformity of the intramedullary device prevented fracture reduction. The device was cut, and open reduction and internal fixation were then performed using a unique approach. No complications occurred, and the patient returned to all daily activities three months after surgery. With increasing rates of operative fixation, the prevalence of peri-implant distal radius fractures is likely to rise. This case highlights the management of a peri-implant fracture involving a dorsal intramedullary nail-plate device, a scenario not previously described in the literature, and underscores the need for a tailored surgical approach.
More Related Videos
07:41An Intramedullary Locking Nail for Standardized Fixation of Femur Osteotomies to Analyze Normal and Defective Bone Healing in Mice
Published on: November 13, 2016
04:41Treatment with Locking Intramedullary Nailing for Intertrochanteric Fracture of the Femur Utilizing a New Awl with a Distal Positioner
Published on: June 6, 2025