Related Experiment Video
Updated: Jan 17, 2026

Author Spotlight: AI-Driven Trypanosome Species Detection from Microscopic Images
Published on: October 27, 2023
Advanced real-time detection of acute ischemic stroke using YOLOv12, YOLOv11, and YOLO-NAS: a comparative study for
Marwa El-Geneedy1,2, Hossam El-Din Moustafa3,4, Hatem Khater5
1Electronics and Communications Engineering Department, Mansoura University, Mansoura, 35516, Egypt. melgeneedy@std.mans.edu.eg.
Abstract:
Acute ischemic stroke (AIS) remains a leading cause of mortality and disability worldwide, demanding diagnostic tools that are both accurate and fast for timely intervention. This study presents a comparative evaluation of three state-of-the-art object detection models-YOLOv12, YOLOv11, and YOLO-NAS-for multi-class AIS detection in magnetic resonance imaging (MRI). The dataset, comprising four categories (Normal, PD-Patient, Acute Ischemic Stroke, and Control), was preprocessed with normalization, resizing, and augmentation, then split into training (70%), validation (20%), and testing (10%). Models were trained and evaluated on identical data, with performance measured by precision, recall, mean average precision at IoU 0.5 (mAP@50), and inference speed. YOLOv11 achieved the highest mAP@50 (98.5%) and balanced precision (95.4%) and recall (96.6%), making it the most reliable across classes. YOLOv12 performed comparably (mAP@50 98.3%, precision 95.2%, recall 96.0%) with slightly slower inference, while YOLO-NAS offered the fastest speed (154 FPS) but lower precision (76.3%. Results highlight the trade-offs between detection accuracy and processing speed, providing guidance for selecting YOLO-based architectures suited to specific clinical workflows such as emergency stroke care. The real-time implementation, accessible via Roboflow, demonstrates the feasibility of deploying these models for rapid, automated AIS detection in clinical settings.
Related Concept Videos
Seizures: Classification
Seizures are typically classified into two main categories: focal and generalized seizures.
Focal Seizures
Focal seizures originate from specific regions of the brain. These seizures are further sub-classified into two types:
Classification of Signals
A continuous-time signal holds a value at every instant in time, representing information seamlessly. In contrast, a discrete-time signal holds values only at specific moments, often denoted as x(n), where...
Acute Coronary Syndrome III: Diagnostic Studies
Classification of Systems-I
Homogeneity dictates that if an input x(t) is multiplied by a constant c, the output y(t) is multiplied by the same constant. Mathematically, this is expressed as:
Imaging Studies for Cardiovascular System IV: CMRI
Imaging Studies VII: Vascular Imaging
