Spectral Computed Tomography for the Detection and Characterization of Communications Between the True and the False
Antoine Janin-Manificat1, Monica Sigovan, Eduardo Davila
1Department of Cardiovascular and Thoracic Radiology, Louis Pradel Hospital, Hospices Civils de Lyon, Bron, France (A.J.M., C.d.B., S.S.M., L.B., P.D., S.B.); University Lyon, INSA-Lyon, University Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, Inserm, Villeurbanne, France (M.S., E.D., S.S.M., L.B., P.D., S.B.); Department of Cardiac Surgery, Marie Lannelongue Hospital, Groupe Hospitalier Paris Saint Joseph, Le Plessis-Robinson, France (B.C.); Global Advanced Technologies, CT, Philips Medical Systems, Haifa, Israel (Y.Y.); Department of Vascular Surgery, Louis Pradel Hospital, Hospices Civils de Lyon, Bron, France (A.M.); University of Lyon, INSA-Lyon, University Claude Bernard Lyon 1, Villeurbanne, France (A.M.).
Objectives:
To compare the performance of conventional CT (conv-CT) and spectral CT (spectral-CT) for the detection and characterization of communications between the true (TL) and false lumen (FL) in aortic dissections, using 4D flow MRI as the reference.
Materials And Methods:
Eighteen patients with type A and type B aortic dissection who underwent 4D flow MRI, conv-CT and spectral-CT were retrospectively analyzed. For each patient, the examinations closest in time, without any intervention in-between, were retrieved and subjectively analyzed by 2 observers, independently for conv-CT and in consensus for MRI and spectral-CT. Communications between the two lumina were identified as: focal alterations in velocities corresponding to jet flows on 4D flow; both intimal tears and/or focal changes of contrast concentration corresponding to jet flows on conv-CT and spectral-CT. The number and location of communications were noted. The direction of the flow was assessed whenever the jet flow was visible. The performance of conventional and spectral-CT was calculated.
Results:
Of the 176 communications detected with 4D flow, spectral-CT allowed visualization of 122(69%) compared with 58 (33%) for observer-1 and 38 (22%) for observer-2 for conv-CT, yielding an accuracy twice as high (63% vs 29% to 30%).Only jet flows, without visible intimal tears, were detected in 0 and 77 (63%) cases for conv-CT and spectral-CT, respectively.The flow was unidirectional FL-TL in 2 cases for MRI and spectral-CT and 1 case for conv-CT, bidirectional in 5 and 3 cases for MRI and spectral-CT, respectively. In all other cases, the direction was TL-FL.
Conclusion:
Spectral-CT outperformed conv-CT for the detection of communications between TL and FL in aortic dissections. Spectral-CT allowed for direct visualization of flow jets, and their direction, through intimal tears.
More Related Videos
Related Concept Videos
Aneurysm II: Clinical Manifestations and Diagnostic Studies
Aortic Regurgitation II: Clinical Features and Diagnostic Tests
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for...
Acute Coronary Syndrome III: Diagnostic Studies
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies