Related Experiment Video
Updated: Jan 17, 2026

Optimized Griess Reaction for UV-Vis and Naked-eye Determination of Anti-malarial Primaquine
Published on: October 11, 2019
Eco-friendly spectrofluorimetric and HPLC-fluorescence methods for simultaneous determination of melatonin and
Shrouk M Abo Elkheir1, Jenny Jeehan M Nasr2,3, Mohamed I Walash2
1Department of Pharmaceutical Analytical Chemistry, Faculty of Pharmacy, Mansoura University, Mansoura, 35516, Egypt. shrouk@mans.edu.eg.
Abstract:
Two eco-friendly, facile, rapid, and highly sensitive analytical methodologies were developed for the concurrent estimation of melatonin and zolpidem tartrate in raw materials and dosage forms. The first approach is a green first derivative synchronous spectrofluorimetric method (Method I), utilizing a wavelength interval (Δλ) of 60 nm and capturing derivative signals at 265.0 nm and 339.0 nm for melatonin and zolpidem, respectively. Method I exhibited excellent linearity over the ranges of 8.0-70.0 ng/mL for melatonin and 10.0-80.0 ng/mL for zolpidem, with detection limits of 1.62 ng/mL and 1.19 ng/mL. The second method (Method II) involves high-performance liquid chromatography coupled with fluorescence detection (HPLC-FD), employing a C18 column and a mobile phase of methanol:0.05% triethylamine (70:30, v/v, pH 5.5) at a flow rate of 1.0 mL/min. Fluorescence detection was performed at 383 nm following excitation at 243 nm. This method achieved linearity within 150.0-1500.0 ng/mL for melatonin and 50.0-700.0 ng/mL for zolpidem, with detection limits of 18.87 ng/mL and 8.86 ng/mL, respectively. Both methods were rigorously validated in accordance with ICH Q2(R1) guidelines, demonstrating high accuracy, precision, and robustness in analyzing commercial dosage forms. Greenness and sustainability were quantitatively assessed using the AGREE and eco-scale metrices, while method applicability and performance were evaluated using the Blue Applicability Grade Index (BAGI), affirming both techniques as efficient and environmentally sustainable tools for routine quality control.
More Related Videos
08:56Detection of Regulated Ergot Alkaloids in Food Matrices by Liquid Chromatography-Trapped Ion Mobility Spectrometry-Time-of-Flight Mass Spectrometry
Published on: November 22, 2024
10:17High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
Related Concept Videos
Photoluminescence: Applications
Sedatives and Hypnotics Drugs: Miscellaneous Agents
Melatonin congeners like ramelteon (Rozerem) and tasimelteon (Hetlioz) selectively bind to melatonin receptors (MT1 and MT2) and thus mimic the actions of melatonin, a hormone that regulates sleep-wake cycles. Tasimelteon is primarily used for non-24-hour sleep-wake disorder, common in blind patients. They are also used to treat conditions like insomnia...
Management of Insomnia
Fluorescence and Phosphorescence: Instrumentation