Related Experiment Video
Updated: Jan 17, 2026

A High-throughput Method for Measurement of Glomerular Filtration Rate in Conscious Mice
Published on: May 10, 2013
Applicability of Creatinine- and Cystatin C-Based Estimated Glomerular Filtration Rate Equations in Patients With
Yuanyuan Wei1,2, Shuang Li1,2, Dong An1,2
1School of Rehabilitation Medicine, Capital Medical University, Beijing, China.
Objectives:
To assess the applicability of Chronic Kidney Disease Epidemiology Collaboration (CKD-EPI) equations and Chinese eGFR Investigation Collaboration (C-eGFR) equations in estimating glomerular filtration rate (GFR) in patients with neurogenic lower urinary tract dysfunction (NLUTD). These equations are based on serum creatinine, cystatin C, or combined creatinine and cystatin C.
Methods:
This prospective study enrolled 142 adult patients with NLUTD. GFR was measured using the dual plasma ⁹⁹mTc-DTPA plasma clearance method. We compared the bias, precision, accuracy and correct classification percentage of six estimated glomerular filtration rate (eGFR) equations, including CKD-EPI creatinine equation (CKD-EPIcr), C-eGFR creatinine equation (C-eGFRcr), CKD-EPI creatinine-cystatin C equation (CKD-EPIcr-cys), C-eGFR creatinine-cystatin C equation (C-eGFRcr-cys), CKD-EPI cystatin C equation (CKD-EPIcys), and C-eGFR cystatin C equation (C-eGFRcys).
Results:
The median (interquartile range [IQR]) of measured GFR (mGFR) was 60.54 (34.66-86.28) mL/min/1.73 m². Both CKD-EPIcr and C-eGFRcr significantly overestimated GFR (median differences of 17.20 and 13.60 mL/min/1.73 m², respectively; both p < 0.01), and P30 values (percentage of estimated GFR within 30% of mGFR) were 51% and 57%, respectively. CKD-EPIcr-cys demonstrated superior performance than C-eGFRcr-cys (median difference: 2.07 vs 9.13 mL/min/1.73 m²; both p < 0.01; P30: 84% vs 69%). CKD-EPIcys achieved the highest P30 (88%), while C-eGFRcys showed minimal bias (median difference: 0.42 mL/min/1.73 m²; p = 0.69). CKD-EPIcr-cys, CKD-EPIcys, and C-eGFRcys all achieved acceptable P30 values and correct classification percentage. CKD-EPIcr-cys performed optimally at mGFR ≥ 60 mL/min/1.73 m², whereas CKD-EPIcys was superior at mGFR < 60 mL/min/1.73 m².
Conclusion:
Creatinine-based equations systematically overestimate GFR in NLUTD patients and should be used with caution. In contrast, cystatin C-based equations-whether used alone (e.g., CKD-EPIcys, C-eGFRcys) or combined with creatinine (e.g., CKD-EPIcr-cys)-demonstrate superior accuracy and should be preferred for GFR estimation in NLUTD patients.
Clinical Trial Registration:
The Chinese clinical trial registration number is ChiCTR2100054934.
Related Concept Videos
Drug Dosing in Renal Diseases: Estimation of Glomerular Filtration Rate Based on Serum Creatinine Concentration
Drug Dosing in Renal Diseases: Measurement of Serum Creatinine Concentration and Clearance
Factors Affecting Renal Clearance: Renal Impairment
One condition associated with renal failure is uremia. Uremia is characterized by impaired glomerular filtration and fluid accumulation in the body. This condition hinders the renal clearance of drugs, resulting in drug accumulation and potential...
Pharmacokinetics in Geriatric Patients: Effect of Age on Drug Excretion
Renal Clearance
Renal clearance refers to the volume of plasma cleared of a specific substance, such as creatinine, per unit of time. To measure clearance, urine samples are collected over a 24-hour period during each bladder voiding, followed by a single blood sample at the...
Serum Studies: Renal Function Tests