Comparison of Two Different Pulsed Field Ablation Systems: The Dual Pulse System Study
Behnam Subin1,2, Corinne Isenegger1,2, David Spreen1,2
1Department of Cardiology, University Hospital Basel, Basel, Switzerland.
Background:
Recently, multiple pulsed field ablation (PFA)-system were introduced for catheter ablation (CA) of atrial fibrillation (AF). However, data comparing procedural performance, the extent of low-voltage areas (LVA), and myocardial injury between different PFA-systems in a real-world setting remain scarce.
Methods:
Consecutive patients undergoing CA for AF were enrolled. PFA was performed using either a Pentaspline catheter-system (PCS) or a loop catheter-system (LCS). The extent of acute antral LVA was assessed using a 3D-electroanatomical mapping system. High-sensitivity cardiac troponin T (hs-cTnT) was measured the day after the procedure to assess myocardial injury.
Results:
A total of 120 patients (median age 67 [59-73] years, 29% female) underwent de novo pulmonary vein isolation (PVI). The PCS-group included 90 patients, while the LCS-group included 30 patients. Acute PVI was achieved in all patients (100%). Procedural times were significantly shorter in the PCS compared to the LCS-group, including total procedure duration (57 [48-67] vs 66 [52-83] min, p = 0.016), left atrial dwell time (38 [32-48] vs 54 [38-65] min, p < 0.001), and ablation duration (17 [12-23] vs 24 [20-33] min, p < 0.001). Acute antral LVA and myocardial injury were significantly lower in the PCS compared to the LCS-group (6.6 [5.0-8.9] vs. 19.2 [16.8-25.4] cm², p < 0.001 and hs-cTnT of 1282 [892-1894] vs 1588 [1281-2110] ng/L, p = 0.029.
Conclusion:
Significant differences were observed between two commercially available PFA-systems. While PCS was associated with significantly shorter procedural time, LCS resulted in a greater extent of acute antral LVA and myocardial injury levels.
More Related Videos
12:45Benefits of Cardiac Resynchronization Therapy in an Asynchronous Heart Failure Model Induced by Left Bundle Branch Ablation and Rapid Pacing
Published on: December 11, 2017
04:58Reduced Procedure Time and Variability with Active Esophageal Cooling During Radiofrequency Ablation for Atrial Fibrillation
Published on: August 25, 2022
Related Concept Videos
Pulse
Pulse Rate and its Significance
Pulse rate, often measured in beats per minute (bpm), reflects the heart rate (HR), which is influenced by numerous factors such as stress, physical activity, and hormonal changes. A normal resting adult pulse rate falls...
Assessment of blood pressure in brachial artery(two-step method)
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Pulse
The pulse serves as a clinical...
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for...