Impact of Pulsed-Field Ablation on the Left Atrial Appendage Diameter-Insights From Intra-Procedural Echocardiography
Nándor Szegedi1, Piotr Gardziejczyk2, Zoltán Salló1
1Heart and Vascular Center, Semmelweis University, Budapest, Hungary.
Introduction:
Concomitant pulmonary vein isolation (PVI) and left atrial appendage (LAA) occlusion (LAAO) have become frequently used therapies. Pulsed-field ablation (PFA), will likely be used for combined PVI plus LAAO procedures. However, there may be concerns regarding the malposition of the LAAO device attributed to the potential tissue edema after PVI.
Aim:
We aimed to compare the LAA's size before and after PVI performed with the pentaspline catheter, measured intraprocedural by intracardiac echocardiography or transesophageal echocardiography.
Methods:
We conducted a multicenter, prospective, observational study investigating PVI using the Farapulse system. The anteroposterior diameter of the left-sided pulmonary vein (LPV), left atrial ridge, and LAA were measured before and after the PFA.
Results:
We enrolled 91 patients aged 63 ± 10 years, 36% were women, and 47% had paroxysmal AF. The most common comorbidities was hypertension (59%). Procedure time and left atrial dwell time were 65 (52-80) min, and 27 (24-32) min, respectively. The diameter of the LAA was not different before and after the PVI (15 [13-18] and 16 [13-19], respectively; p = 0.756). On the other hand, the diameter of the left atrial ridge (7 [6-8] and 8 [6-8]) and the LPV (13 [10-15] and 13 [11-15]) was smaller before ablation compared to the diameter after PVI (p < 0.0001 for both). No major complications occurred.
Conclusion:
LAA anteroposterior diameter does not change after PVI with PFA. Although there is a significant change in the anteroposterior diameters of the LPV and the left atrial ridge, it does not seem clinically relevant. If significant edema formation is detected in a single case after PVI, postponing the LAAO procedure should be considered.
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Location and Orientation of the Heart
Chambers of the Heart
Deoxygenated blood from the body is received in the right...
Heart Valves
The AV valves prevent the backflow of blood from the ventricles to the atria during ventricular contraction. These valves function with the assistance of the chordae tendineae and papillary muscles. When the ventricles are relaxed, the chordae tendineae are slack, allowing blood to flow from the atria into the...
Cardiac Catheterization II: Right Heart Catheterization
Cardiac Catheterization III: Left Heart Catheterization