Open-Source Miniature Fluorimeter to Monitor Real-Time Isothermal Nucleic Acid Amplification Reactions in Resource-Limited Settings
Published on: February 3, 2021
Electrostatically Adjustable AuNR-Mediated Thermal-Start Isothermal Nucleic Acid Amplification.
Hanhua Li1, Jiale Gao2,3, Huiwen Xiong1,4
1Department of Clinical Laboratory, Institute of Pediatric Infection, Immunity, and Critical Care Medicine, Shanghai Children's Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai 200062, China.
Gold nanorods (AuNRs) enable a hot start for loop-mediated isothermal amplification (LAMP), significantly reducing false positives in African horse sickness virus (AHSV) detection. This optimized LAMP assay demonstrates high sensitivity and repeatability for potential clinical use.
Area of Science:
- Biotechnology
- Molecular Diagnostics
- Nanotechnology
Background:
- Loop-mediated isothermal amplification (LAMP) is a promising technique for rapid nucleic acid detection.
- A significant limitation of LAMP is the high occurrence of false-positive results.
- Existing methods require optimization to improve specificity and reliability.
Purpose of the Study:
- To develop an optimized LAMP assay using gold nanorods (AuNRs) to mitigate false positives.
- To evaluate the performance of AuNR-mediated LAMP for detecting African horse sickness virus (AHSV).
- To assess the assay's sensitivity, selectivity, and repeatability.
Main Methods:
- Utilized gold nanorods (AuNRs) to induce a hot start effect in LAMP reactions.
- The hot start mechanism involves primer adsorption and controlled single-stranded DNA (ssDNA) release at approximately 50 °C.
- Tested the AuNR-mediated LAMP assay for AHSV detection against other DNA fragments and varying magnesium concentrations.
Main Results:
- The AuNR-mediated LAMP assay demonstrated high selectivity, distinguishing AHSV from other DNA fragments even with high magnesium concentrations.
- Achieved excellent sensitivity with a detection limit of 100 copies/μL for AHSV.
- Showed good repeatability across a temperature range of 50–65 °C (optimal), with a coefficient of variation of Tt less than 5%.
Conclusions:
- Optimization of LAMP using AuNRs effectively reduces false positives, enhancing diagnostic accuracy.
- The AuNR-mediated LAMP assay is highly sensitive, specific, and repeatable for AHSV detection.
- This method holds significant potential for reliable and rapid clinical diagnosis.