Study on the prediction of short-term clinical changes after cerebral infarction using carotid plaque ultrasound
Mingqiu Li1, Shiwen Weng2, Qian Song1
1Department of Ultrasound, Beijing Chaoyang Hospital, Capital Medical University, Beijing, China.
Objective:
To evaluate the value of ultrasound strain elastography in assessing carotid plaque stiffness for predicting short-term clinical changes after cerebral infarction.
Methods:
Patients with cerebral infarction and carotid atherosclerotic plaque identified through routine ultrasound examination at the Ultrasound Department of Beijing Chaoyang Hospital, Capital Medical University, were selected for this study. All patients underwent strain elastography. Based on changes in their clinical conditions within 30 days following cerebral infarction, they were divided into a deterioration group and a non-deterioration group. The differences between the two groups in terms of strain elastography results were compared for statistical significance. Logistic regression analysis was conducted to analyze factors affecting short-term clinical changes in patients with cerebral infarction. The receiver operating characteristic (ROC) curve was drawn.
Results:
A total of 110 patients were included in this study (83 males and 27 females, average age: 60.02 ± 10.67 years). The carotid plaque strain elastography value, arterial wall strain elastography value and plaque stiffness were1.17 ± 0.40, 0.53 ± 0.16 and 2.33 ± 0.97 in the deterioration group, 1.73 ± 0.58, 0.59 ± 0.18 and 3.04 ± 1.00 in the non-deterioration group. The differences between the two groups were statistically significant about carotid plaque strain elastography value and plaque stiffness. The AUC values for predicting non-deterioration after cerebral infarction were 0.790 for carotid plaque strain elastography value, 0.608 for arterial wall strain elastography value, and 0.740 for plaque stiffness.
Conclusion:
Carotid plaque ultrasound strain elastography can be utilized to assess short-term clinical changes after cerebral infarction. Patients who experience clinical deterioration have lower carotid plaque strain elastography values, indicating that this parameter is more effective in predicting the absence of deterioration after cerebral infarction.
More Related Videos
09:33A Methodological Approach to Non-invasive Assessments of Vascular Function and Morphology
Published on: February 7, 2015
13:45A Method to Study the Correlation Between Local Collagen Structure and Mechanical Properties of Atherosclerotic Plaque Fibrous Tissue
Published on: November 11, 2022