Abstract:
X-ray imaging allows for the visualization of the internal structure of an object. However, the capture of motion trajectories of weakly absorbing objects in complex backgrounds remains challenging due to low contrast and structural overlap. To address this issue, move contrast X-ray imaging (MCXI) is employed to enhance dynamic features without the use of contrast agents and to provide strong robustness against noise. A fringe-based background model was constructed to simulate and analyze variations in motion trajectories under various influencing factors, including relative contrast, motion speed, background fluctuation frequency, and noise level. Quantitative metrics-such as trajectory intensity, integrity, and signal-to-noise ratio-were used to evaluate the performance of the proposed method. MCXI enables the identification of motion paths and spatial velocity distributions of weakly absorbing objects, even under high-noise conditions, demonstrating high robustness and sensitivity. The effectiveness, sensitivity, and noise resistance of the method were validated through experiments involving oil-water motion. In addition, the integration of the CUDA acceleration algorithm significantly improves the efficiency of processing high-throughput dynamic data.
Related Concept Videos
Linear Approximation in Frequency Domain
In contrast, nonlinear systems do not inherently possess these properties. However, for small deviations around an operating point, a nonlinear system can often be approximated as linear....
Frequency-Domain Interpretation of PD Control
The proportional control gain, combined with the...
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Aliasing
If the sampling frequency is below the Nyquist rate, these replicas overlap, preventing the original...
Discrete Fourier Transform